Maintenance and technical data
87
990267EN ind. A
Maintenance and technical data
Preparing system for winter rest
The job computer is left on the field sprayer over the winter and must not be removed.
However the sprayer must be parked in an area that is dry.
Technical data
Technical data for the job computer
Technical data of job computer F1
Processor
16 bit Fujitsu MB 90F345 with flash memory
Memory:
Flash 512 kB; RAM 20 kB; 64 kBit I
2
C-Bus EEPROM
Connections:
▪
1 x 16-way connector for power supply, CAN (J1939 or ISO
11783)
▪
42-way connector for sensors and actuators and V24
Power supply:
9 - 16 V DC
Power consumption:
240 mA (at 13.8V without power output, without supply to external
sensors)
Temperature range:
-20 to +70 ºC (in accordance with IEC68-2-14-Nb, IEC68-2-30 and
IEC68-2-14Na)
Housing:
Anodized aluminum continuous cast casing, lid with pressure
compensation element and stainless steel screws
Protection degree:
IP66K (dustproof and protected against hose water at elevated
pressure in accordance with DIN40050 Part 9: 1993)
Environmental tests:
Vibration and impact test in accordance with IEC68-2
Dimensions:
262 mm x 148 mm x 62 mm (LxWxH)
Weight:
0.84 kg
Technical data of job computer F2
Processor
16 bit Fujitsu MB 90F345 with flash memory
Memory:
Flash 512 kB; RAM 20 kB; 64 kBit I
2
C-Bus EEPROM
Connections:
▪
1 x 16-way connector for power supply, CAN (J1939 or ISO
11783)
▪
optional 1 x 16-way connector for voltage supply, CAN (J1939 or
ISO 11783)
11
11.1
11.2
11.2.1