Preparing job computer sprayer for use
48
990267EN ind. A
Configuring sections for the use of wide area nozzles
You configure sections for the use of wide area nozzles in this way:
The job computer was configured by the field sprayer manufacturer for the use of wide area
nozzles.
You have read chapter "Entering the number of nozzles per section [
➙
42]".
1.
Switch to the "Sections" screen:
2.
In the line "Total sections" increase the number of sections. For each wide area nozzle add a
section.
3.
- Choose sections to which a wide area nozzle is fitted. These are the first and last
sections.
4.
Set the number of nozzles on each of these sections so it reaches the spray range of the wide
area nozzles.
5.
Leave the "Sections" screen.
6.
Check if the "Working width" is set correctly. If not, correct the "Working width" parameter.
7.
Check whether the spray geometry is set correctly.
Tank filling
After each fill-up of the spray liquid tank, you can tell the job computer how much water you added.
Depending on what additional equipment is fitted to your field sprayer, the process may be different.
In this you can:
▪
Fill up the tank manually without additional systems
▪
Fill up the tank with TANK-Control
Filling up the tank manually without additional systems
If you fill up the spray liquid container manually without any additional systems, you need to enter the
new tank content manually on the terminal.
Function icon
Function
Tank was fully filled up.
Set tank content to 0 liter.
Enter the new tank content in this way if you have fully filled up the liquid container:
1.
Switch to screen "Tank filling – manual":
Procedure
6.8
Methods
6.8.1
Controls