Preparing job computer sprayer for use
47
990267EN ind. A
3.
and
- Set spray pressure to 3 bar.
4.
Using a measuring beaker collect the water from several nozzles for one minute long each.
5.
Calculate average application rate.
6.
- Stop applying.
7.
- Activate automatic mode.
8.
Switch to the "NOZZLE/PRESSURE" screen:
9.
In the "Nozzle" line – select nozzle for calibration. Standard nozzles are referred to by their
colors.
10.
- Bring up second page.
11.
- In the box below the line "new reference point" enter the calculated average quantity
in l/min.
12.
For undefined nozzles you must also enter the nozzle's minimum output in the "2nd reference
point" parameter.
⇨
You have calibrated the selected nozzle.
Configuring wide area nozzles
Wide area nozzles are nozzles fitted to the outer edge of the boom. They can spray further than the
normal nozzles.
Wide area nozzles and corner nozzles cannot be used at the same time.
Determining the spray range of the wide area nozzles
The spray range of a wide area nozzle is considered by the job computer to be the spray range of
several normal nozzles.
How many nozzles this is exactly depends on the spray range of the nozzles and the spray range of
the wide area nozzle.
A field sprayer is configured as follows:
Working width: 18 m
Total number of normal nozzles: 36
Spray range of the wide area nozzles: 2 m
Spray range of a normal nozzle: 18 m 36 nozzles = 50 cm per nozzle
The spray range of the wide area nozzles corresponds to the spray range of four normal nozzles:
200(cm) : 50(cm) = 4
6.7.5
Example