Preparing job computer sprayer for use
39
990267EN ind. A
⇨
The following screen will appear:
⇨
The line "Measured flow" will display the previous flow rate.
4.
- Start spreading.
5.
Go to one nozzle and for 60 seconds carefully collect the water sprayed by using the measuring
beaker prepared.
6.
Write down the water quantity sprayed.
7.
Repeat the last two steps on several nozzles.
8.
Determine and note down an average of several measurements.
9.
- Stop applying.
⇨
The application will be stopped.
10.
- Stop calibration.
⇨
Line "Real flow" appears.
11.
Enter the average applied quantity in liters in the "Real flow" line.
12.
- Exit screen.
⇨
The value of the parameter "Pulses main flow" will be updated.
⇨
You have calibrated the flow meter with the nozzle method.
Manually entering the number of pulses per liter for the flow meter
If you know the precise number of pulses per liter for the flow meter, you can enter this value
manually.
1.
Switch to the "Parameters" screen:
6.4.3
Procedure