Preparing job computer sprayer for use
44
990267EN ind. A
Area with current nozzle settings
Selected nozzle
Current nozzle output at a specific pressure.
If you change the pressure, the nozzle output
will be adjusted automatically.
Type of nozzle:
- standard nozzle
- undefined nozzle
Calibration status
In the following cases you must select the nozzle type:
▪
If the field sprayer regulation works without a flow meter.
▪
If the field sprayer has no pressure sensor and the spray pressure should be shown.
The nozzle selection list contains 15 standard nozzle types as defined by ISO 10625 and 4 user-
specific, freely configurable nozzles types A, B, C and D.
The following table shows an overview of the nozzles, their color and output:
Nozzle color in accordance
with ISO 10625
ISO identifier
Output in l/min. at 3 bar
light violet
0050
0.2
light pink
0075
0.3
orange 01
0.4
Green 015 0.6
Yellow
02
0.8
violet 025 1.0
blue 03 1.2
purple 035 1.4
Red 04 1.6
brown 05
2.0
grey 06 2.4
white 08 3.2
light blue
10
4.0
When to enter?