Control by keypoint
User Manual -
TP8-64
5-8
5.3
SPECIAL OPERATING CONDITIONS
5.3.1
FALSE KEY ALARM
The alarm is released when an unknown key is introduced into the key reader.
In case of false key alarm, the yellow OCG or general alarm LED starts blinking.
The control unit in question is disabled for 2 minutes. Simultaneously the buzzers of the consoles connected are
activated and the OCG and key LED of all the key readers and the consoles as well as the LED 6 general alarm of the
electronic keypads start blinking.
To stop the alarm introduce a key or enter a user code (master or standard user) on one of the control units connected.
5.3.2
SIMULTANEOUS ARMING BY SEVERAL CONTROL UNITS
In case of control by key reader with mini keypad (TP SK6N), while the control unit is in use, on all the other key
readers with mini keypad the green key LED is blinking and all the processes are inhibited exception made of the
release of panic alarm.
5.3.3
SIMULTANEOUS ARMING WITH CODE AND KEY
During the arming process by console or electronic keypad, all the key readers are disabled.
When trying to arm the control panel by key, the 4 LED on the key readers blink for approximately 3 seconds.
5.3.4
AUTOMATIC DISARMING FOR ALARM
If you introduce the key in presence of program alarm, all the programs associated to the key and in alarm are disarmed
automatically.
5.3.5
AUTOMATIC COMMUNICATOR BLOCK
If enabled by the holder of the master code, upon disarming of the program the active telephone channels are blocked
automatically.
5.3.6
TROUBLE/GENERAL ALARM
If a trouble/general alarm is active (the corresponding LED is blinking), arming of the control panel by key is not
permitted unless the key has been enabled for the by-pass of the general alarms.
WARNING
It is possible to use only one control unit at a time.
Summary of Contents for TP8-64
Page 4: ...IV UserManual TP8 64...
Page 8: ...Index User Manual TP8 64 4...
Page 10: ...Notes User Manual TP8 64 II...
Page 26: ...Signaling UserManual TP8 64 2 12...
Page 42: ...Programming UserManual TP8 64 3 16...
Page 45: ...TP8 64 UserManual Control by console 4 3 OPERATIONSWITHOUTCODE...
Page 47: ...TP8 64 UserManual Control by console 4 5 LCD200CONSOLE LCD300 SCONSOLE...