Control by keypoint
User Manual -
TP8-64
5-6
EXIT TIME
The zones defined as delayed upon arming observe the exit time programmed by the
installer.
If the program selected contains delayed zones, on expiry of the zone exclusion time
follows the exit time and the program in question is only armed on expiry of the exit
time. Once the exit time has expired, the program LED becomes lit and remains lit until
disarming of the program.
If the program selected does not contain delayed zones, on expiry (or abort) of the zone
exclusion time, the program in question is armed and the corresponding LED becomes
lit immediately.
Remove the key from the key reader.
5.2.1.2
MULTIPLE ARMING
Introduce the key into the key reader.
The LED of the first program associated to the key blinks quickly for 3 seconds.
After 3 seconds, the LED corresponding to the program selected starts blinking slowly
and the 10-seconds zone exclusion time is started.
Remove the key from the key reader.
ZONE EXCLUSION TIME
For 10 seconds after selecting the program, it is possible to exclude manually the open
zones with a procedure explained lateron.
If you do not wish to exclude any zone, it is however possible to select other programs
without deselecting the one you have only just selected by introducing the key into the
key reader again.
EXIT TIME
The zones defined as delayed upon arming observe the exit time programmed by the
installer.
If the programs selected contain delayed zones, on expiry of the zone exclusion time
follows the exit time and the programs in question are only armed on expiry of the exit
time.
Once the exit time has expired, the program LED become lit and remain lit until
disarming of these programs.
If the programs selected do not contain delayed zones, on expiry (or abort) of the zone
exclusion time, the programs in question are armed and the corresponding LED become
lit immediately.
5.2.1.3
EXCLUSION OF OPEN ZONES
After selecting the programs to be armed, during the 10-seconds zone exclusion time, if
there are open zones, the yellow OCG LED is blinking.
A zone may result open for instance in case of fault of the detector connected.
To arm the programs selected with exclusion of open zones introduce and remove the
key until the program required is selected.
Reintroduce the key and leave it in the key reader for the entire zone exclusion time.
The zones remain excluded until disarming of the program. They are activated
automatically again the next time the program is armed.
5.2.2
DISARMING
5.2.2.1
SINGLE ARMING
Introduce an electronic key enabled for the program armed into the key reader.
The program is disarmed and the corresponding led is switched off.
Remove the key from the key reader.
WARNING
If the key is removed and reintroduced within 3 seconds the next program is selected etc. until
selecting the third program after which the key reader returns to stand-by.
This valid only if the first 3 programs of the control panel are associated to the key. The programs not
associated are not viewed nor activated.
WARNING
If the open zones are not excluded, on expiry of the zone exclusion time (and perhaps the exit time) the
programs are armed and the open zones are activated. As a consequence, the alarm is released.
Summary of Contents for TP8-64
Page 4: ...IV UserManual TP8 64...
Page 8: ...Index User Manual TP8 64 4...
Page 10: ...Notes User Manual TP8 64 II...
Page 26: ...Signaling UserManual TP8 64 2 12...
Page 42: ...Programming UserManual TP8 64 3 16...
Page 45: ...TP8 64 UserManual Control by console 4 3 OPERATIONSWITHOUTCODE...
Page 47: ...TP8 64 UserManual Control by console 4 5 LCD200CONSOLE LCD300 SCONSOLE...