![Tecnoalarm TP8-64 User Manual Download Page 39](http://html1.mh-extra.com/html/tecnoalarm/tp8-64/tp8-64_user-manual_1071819039.webp)
TP8-64
- User Manual
Programming
3-13
3.10
PROGRAMMING OF THE CONSOLES
Select the consoles menu and confirm by clicking on the
#
key.
+
yw
to select the console
+
#
to confirm
The control panel provides up to 15 consoles. The consoles can be configured
individually so as to allow determined functions relating to determined programs.
Submenus
z
Volume
Permits volume adjustment for the voice report at 4 different
settings (mute, low, medium, high)
z
Audio always
Enables the console permenantly for the voice report of the
operations executed (e.g. arming or disarming)
Commands available
+
yw
to select the option
+
EXIT
to confirm and quit
3.11
EXCLUSION OF MODULES/ZONE
Select the exclusion menu and confirm by clicking on the
#
key.
+
#
to confirm
Permits to exclude volontarily modules or single zones of the system, e.g. in case of
misfunction.
Submenus
z
Zones
Exclusion of the zones selected (from 1 to 64)
z
WL sirens
Exclusion of the wireless sirens selected (from 1 to 4)
z
WL consoles
Exclusion of the wireless consoles selected (from 1 to 4)
z
WL keys
Exclusion of the wireless keys selected (from 1 to 32)
z
Consoles
Exclusion of the consoles selected (from 1 to 15)
z
Key readers
Exclusion of the key readers selected (from 1 to 15)
z
Superv. brds
Exclusion of the supervisory boards/output espansions
selected (from 1 to 7)
z
Tecnocell
Exclusion of the telephone communicator with GSM module
z
Modules
Exclusion of the modules selected (from 1 to 14)
z
WL module
Exclusion of the wireless module selected (1 or 2)
3.11.1
EXCLUSION OF ZONES
+
yw
to select the zone
+
#
to confirm
Commands available
+
yw
to select the zone 1...64
+
#
to exclude the zone
+
*
to enable the zone
+
EXIT
to confirm and quit
Viewing of the current settings
[ ]
zone enabled
[ # ]
zone disabled (excluded)
The procedure of exclusion is the same for all the other devices.
Menu
15
Consoles
Consoles
1
Console 01
4
4
4
4
4
Menu
17
Exclusion
Exclusion
1
Zone
Zone
1
Ctrl panel Z4 [ # ]
Summary of Contents for TP8-64
Page 4: ...IV UserManual TP8 64...
Page 8: ...Index User Manual TP8 64 4...
Page 10: ...Notes User Manual TP8 64 II...
Page 26: ...Signaling UserManual TP8 64 2 12...
Page 42: ...Programming UserManual TP8 64 3 16...
Page 45: ...TP8 64 UserManual Control by console 4 3 OPERATIONSWITHOUTCODE...
Page 47: ...TP8 64 UserManual Control by console 4 5 LCD200CONSOLE LCD300 SCONSOLE...