TP8-64
- User Manual
Control by console
4-11
4.3.2
AUTOMATIC BY-PASS ACTIVATION
TThe control panel can be partset automatically using the 16 timers. Therefore, it is
possible to schedule by-pass with a determined frequency and at a determined time
acting on determined programs.
At the time programmed the timer partsets the programs associated.
4.3.3
ACTIVATION OF BY-PASS DURING THE ACCESS
PERIODS
It is possible define up to 8 access periods of the codes. As a consequence the codes
are enabled for by-pass during the access periods associated by the installer or holder
of the master code only.
4.3.4
DEACTIVATION OF BY-PASS
Enter a code enabled for by-pass (master or standard user enabled for the programs
armed) followed by the number of the program to be reactivated in its integrity, e.g.:
+
66778
+
1
On the display is viewed
Deact. by-pass
followed by the program to be reactivated in its
integrity.
The LED of the program previously partset becomes lit.
4.3.5
AUTOMATIC DEACTIVACION OF BY-PASS
The by-pass can be deactivated automatically using the 16 timers. Therefore, it is
possible to schedule deactivation of the by-pass with a determined frequency and at a
determined time acting on determined programs.
At the time programmed the timer deactivates the by-pass and reactivates the programs
associated in their integrity.
WARNING OF AUTOMATIC ARMING
At the time and for the period of time programmed by the installer on the display is
viewed a warning of imminent automatic arming and blink the yellow program LED on the
console.
According to programming, the buzzers of the consoles are activated, too.
4.3.6
DEACTIVATION OF BY-PASS ON EXPIRY OF MAXIMUM
BY-PASS TIME
If a maximum by-pass time has been programmed by the installer, on expiry of this time
the by-pass is automatically deactivated.
WARNING OF ARMING
For a period of time programmed by the installer before expiry of the maximum by-pass
time, on the display is viewed a warning of imminent arming due to expiry of maximum
by-pass time and the yellow program LED on the console become lit.
According to programming, the buzzers of the consoles are activated, too.
WARNING
The zones excluded are those associated to the by-pass function and included in the program/s
selected.
WARNING
Outside the access periods associated the codes are not accepted by the control panel and any
attempt at acceding to the system will have no effect.
When trying to do so, on the display is viewed
ACCESS ! DENIED !
.
Deact. by-pass
Program 1
Arming
Automatic
Arming
Deact. by-pass
Summary of Contents for TP8-64
Page 4: ...IV UserManual TP8 64...
Page 8: ...Index User Manual TP8 64 4...
Page 10: ...Notes User Manual TP8 64 II...
Page 26: ...Signaling UserManual TP8 64 2 12...
Page 42: ...Programming UserManual TP8 64 3 16...
Page 45: ...TP8 64 UserManual Control by console 4 3 OPERATIONSWITHOUTCODE...
Page 47: ...TP8 64 UserManual Control by console 4 5 LCD200CONSOLE LCD300 SCONSOLE...