Control by console
User Manual -
TP8-64
4-8
Autom.
Arming
4.1.4
ARMING THROUGH KEY ZONE
he control panel can be armed through a contact connected to a zone programmed by
the installer as key zone.
Every time the contact is opened, all the programs that contain the key zone are armed.
EXIT TIME
The zones defined as delayed upon arming observe an exit time programmed by the
installer. If the programs selected contain delayed zones, these are only armed on
expiry of the exit time. Once the exit time has expired, the yellow program LED are lit
and remain lit until disarming of these programs. If the programs selected do not contain
delayed zones, the programs in question are armed immediately.
4.1.5
AUTOMATIC ARMING
The control panel can be armed automatically using the 16 timers. Therefore, it is
possible to schedule arming with a determined frequency and at a determined time
acting on determined programs.
WARNING OF AUTOMATIC ARMING
At the time and for the period of time programmed by the installer on the display is
viewed a warning of imminent automatic arming and blink the yellow program LED on the
console.
According to programming, the buzzers of the consoles are activated, too.
EXIT TIME
The zones defined as delayed upon arming observe an exit time programmed by the
installer. If the programs selected contain delayed zones, these are only armed on
expiry of the exit time.
Once the exit time has expired, the yellow program LED become lit and remain lit until
disarming of these programs. If the programs selected do not contain delayed zones,
the programs in question are armed immediately on disappearance of warning of
automatic arming.
ABORT OF AUTOMATIC ARMING
Automatic arming can be aborted in the following way:
z
Enter the master code
z
Select the timer menu
z
Select the timer to be blocked
4.1.6
ARMING DURING ACCESS PERIODS
It is possible to define up to 8 access periods of the codes. As a consequence, the
codes are enabled for arming and disarming during the access periods associated by
the installer or the holder of the master code only.
WARNING
Arming through key zone is direct, i.e. the exclusion of zones is
not
possible.
It is not permitted in case of trouble/general alarm or fault (low battery, power failure etc.). At the
attempt at doing so, on the display is viewed
! ARM. DENIED !
followed by the kind of alarm.
WARNING
Automatic arming is direct, i.e. the exclusion of zones is
not
possible.
It is always executed even in presence of trouble/general alarm or fault (low battery, power failure etc.).
WARNING
Automatic arming can only be aborted by the holder of the master code.
WARNING
Outside the access periods associated the codes are not accepted by the control panel and any
attempt at acceding to the system will have no effect. When trying to do so, on the display is viewed
ACCESS ! DENIED !
.
Summary of Contents for TP8-64
Page 4: ...IV UserManual TP8 64...
Page 8: ...Index User Manual TP8 64 4...
Page 10: ...Notes User Manual TP8 64 II...
Page 26: ...Signaling UserManual TP8 64 2 12...
Page 42: ...Programming UserManual TP8 64 3 16...
Page 45: ...TP8 64 UserManual Control by console 4 3 OPERATIONSWITHOUTCODE...
Page 47: ...TP8 64 UserManual Control by console 4 5 LCD200CONSOLE LCD300 SCONSOLE...