Page A14-16
Section 3 – Emergency Procedures (Additional Controls)
Smoke and Fire
3
rd
Edition, Rev. 0
6. S
MOKE
A
ND
F
IRE
6.1. E
NGINE FIRE ON THE GROUND
1.
Fuel Selector
OFF
2.
Electrical fuel pump
OFF
3.
Ignition key
OFF
4.
Throttle Hand Control
FULL POWER (
ROTATE CLOCKWISE)
or: Throttle standard control
FULL POWER (fully in)
5.
Cabin Heat
OFF
6.
Generator &Master Switches
OFF
7.
Parking Brake
ENGAGED
8.
Aircraft Evacuation
carry out immediately
6.2. E
NGINE
F
IRE
D
URING
T
AKEOFF
BEFORE ROTATION: ABORT TAKE OFF
1.
Throttle Hand Control
IDLE (
ROTATE COUNTER-CLOCKWISE)
or: Throttle standard control
IDLE (fully out)
2.
Rudder
Keep heading control
3.
Brakes
As required
With aircraft under control
1.
Fuel Selector
OFF
2.
Electrical fuel pump
OFF
3.
Ignition key
OFF
4.
Cabin Heat
OFF
5.
Generator & Master Switches
OFF
6.
Parking Brake
ENGAGED
7.
Aircraft Evacuation
carry out immediately