SYNCHRO : Service & maintenance manual - rev. 7.1
Page 7.23
Figure 7.4-4
1.
Remove the adhesive tape which keep the
receiver in its housing.
6.
Remove the cable tie and extract the cardio
receiver from the protection sponge
(e)
.
Figure 7.4-5
2.
Extract the cardio receiver as shown in the
figure
(f)
and disconnect the connector as
shown in the figure
(g)
.
7.
Remove the receiver and replace if it is
necessary.
Figure 7.4-6
3.
Rewind the receiver in the sponge and
rewind all in a cable tie for look all.
ATTENTION: Position the receiver so
that the coil is oriented upward and
towards the user, as shown in the
figure at the side.
To reassemble the cardio receiver, carry out the
above steps in reverse order.