![Technogym SYNCHRO Excite + Service And Maintenance Manual Download Page 135](http://html1.mh-extra.com/html/technogym/synchro-excite/synchro-excite_service-and-maintenance-manual_1070236135.webp)
SYNCHRO : Service & maintenance manual - rev. 7.1
Page 7.37
Figure 7.11-4
Take note about the measure “X” on
the tighten device adjusting bolt.
Figure 7.11-5
4.
Loosen the nut
(f)
and the bolt
(g)
, with a
17mm wrench; to loosen the tension on the
belt.
Figure 7.11-6
5.
Mark the position of the pillow blocks using
a pen.
6.
Unscrew the nut
(h)
using a 17mm wrench,
locking the bolt on the opposite side, as
shown in the figure at the side.
AVVERTENZA: If working on plastic
support, pay attention to lock down
the screws, using a torque wrench
setting of 20Nm and no more.