Page 9.25
9.5.1.1.
Table of configuration parameters
To correctly display the parameter values, you need to load them from the low kit,
using the “Read from low kit” function.
After any changes to the parameter values, you need to save them in the low kit using
the “Write to low kit” function
Id
(Par.)
Units
Name
Description
VISIO
Powered.
1
decimal
[Rt]
Transmission Ratio
141
2
[Rvel]
Speed ratio
1
3
mA
[Im]
Minimum braking
0
4
W
[Pmc]
Constant maximum power
200
5
in
cents
[Km]
Power factor correction (constant torque)
100
6
0.1N
[Ca]
User friction torque
60
7
°C
[Tea]
Maximum temperature on the coil
125
8
User rpm
[RPMmin]
Minimum user SPM (start cut braking ramp)
35
9
Type/sec
[RpmF1]
Flywheel target RPM speed in standby
(and power-on speed for self powered)
1
10
User rpm
[RpmF2]
Rpm filter threshold
75
11
[Rvel]
Speed ratio (decimal part)
60
12
0.1N
[D_Ca]
User delta friction torque
10
13
-
-
Enable flag for registers
at address ≥ 100
-
Summary of Contents for SYNCHRO Excite +
Page 1: ...S Sy yn nc ch hr ro o E X C I T E REV 7 1 ...
Page 2: ......
Page 4: ......
Page 10: ...SYNCHRO Excite Service maintenance manual rev 7 1 Page vi Page intentionally left blank ...
Page 50: ...SYNCHRO Excite Service maintenance manual rev 7 1 Page 3 18 Page intentionally left blank ...
Page 98: ...SYNCHRO Excite Service maintenance manual rev 7 1 Page 6 40 Page intentionally left blank ...
Page 182: ...SYNCHRO Excite Service maintenance manual rev 7 1 Page 9 26 Page intentionally left blank ...
Page 184: ...SYNCHRO Excite Service maintenance manual rev 7 1 Pagina 10 2 Page intentionally left blank ...
Page 195: ......