SYNCHRO : Service & maintenance manual - rev. 7.1
Page 9.16
9.3.3.3.
Default Setting
To load the default parameter values, scroll using the
+/-
effort level keys until the display shows:
DEFAULT SETTING ?
Press
ENTER.
Display shows:
CONFIRM ?
Press
ENTER
to write the default values to the low kit, and return to the upper menu level by
pressing
CLEAR
for a few seconds.
To write these parameters to the low kit, use the “Write to low kit” function.
9.3.3.4.
Table of configuration parameters:
Id
(Par.)
Units
Name
Description
LED
powered
Self-powered
1
decimal
[Rt]
Transmission Ratio
166
166
2
[Rvel]
Speed ratio
1
1
3
mA
[Im]
Minimum braking
0
0
4
W
[Pmc]
Constant maximum power
200
200
5
in cent
[Km]
Power factor correction (constant torque)
100
100
6
0.1N
[Ca]
User friction torque
23
23
7
°C
[Tea]
Maximum temperature on the coil
125
125
8
User
Rpm
[RPMmin
]
Minimum user SPM
(start cut braking ramp)
35
35
9
Type/sec [RpmF1]
Flywheel target RPM speed in standby
(and power-on speed for self powered)
1
1
10
User Rpm [RpmF2]
Rpm filter threshold
75
75
11
[Rvel]
Speed ratio (decimal part)
60
60
12
0.1N
[D_Ca]
User delta friction torque
6
6
13
-
-
Enable flag for registers at address ≥ 100
-
-
Summary of Contents for SYNCHRO Excite +
Page 1: ...S Sy yn nc ch hr ro o E X C I T E REV 7 1 ...
Page 2: ......
Page 4: ......
Page 10: ...SYNCHRO Excite Service maintenance manual rev 7 1 Page vi Page intentionally left blank ...
Page 50: ...SYNCHRO Excite Service maintenance manual rev 7 1 Page 3 18 Page intentionally left blank ...
Page 98: ...SYNCHRO Excite Service maintenance manual rev 7 1 Page 6 40 Page intentionally left blank ...
Page 182: ...SYNCHRO Excite Service maintenance manual rev 7 1 Page 9 26 Page intentionally left blank ...
Page 184: ...SYNCHRO Excite Service maintenance manual rev 7 1 Pagina 10 2 Page intentionally left blank ...
Page 195: ......