SYNCHRO : Service & maintenance manual - rev. 7.1
Page 6.38
6.15.2.
H
AND
S
ENSOR
HUMAN BODY “CONTINUITY”: it’s well known that for somebody it’s very
difficult, nearly impossible, to measure their HR using the hand sensors. This due to a
lot of possible causes which could fake the “quality” of the contact between the human
skin and the HS plates, as: hands only just washed or particularly dry, acidity of the
skin and/or a particular body fat mass index. For these people it’s suggested to wear
the chest belt transmitter.
HS CORRECT USE: Grasp both the upper and lower plate avoiding to clench them
too hardly. Avoid to wash the hands using soaps that can dry the skin too much.
THE TELEMETRIC HR
SIGNAL IS INCORRECT
(Hand Sensor)
Check the state of
wear of cable.
The problem is f ixed?
OK.
NO
1
YES
OK.
NO
Check the HS Board SW
v ersion and the grounding
of the receiv er.
The problem is f ixed?
YES
HS def ectiv e.
Replace it.
2
Summary of Contents for SYNCHRO Excite +
Page 1: ...S Sy yn nc ch hr ro o E X C I T E REV 7 1 ...
Page 2: ......
Page 4: ......
Page 10: ...SYNCHRO Excite Service maintenance manual rev 7 1 Page vi Page intentionally left blank ...
Page 50: ...SYNCHRO Excite Service maintenance manual rev 7 1 Page 3 18 Page intentionally left blank ...
Page 98: ...SYNCHRO Excite Service maintenance manual rev 7 1 Page 6 40 Page intentionally left blank ...
Page 182: ...SYNCHRO Excite Service maintenance manual rev 7 1 Page 9 26 Page intentionally left blank ...
Page 184: ...SYNCHRO Excite Service maintenance manual rev 7 1 Pagina 10 2 Page intentionally left blank ...
Page 195: ......