![Technogym SYNCHRO Excite + Service And Maintenance Manual Download Page 78](http://html1.mh-extra.com/html/technogym/synchro-excite/synchro-excite_service-and-maintenance-manual_1070236078.webp)
SYNCHRO : Service & maintenance manual - rev. 7.1
Page 6.20
6.10.
THERE IS NO RESISTANCE
The machine will not produce resistance if:
•
the display board is not receiving a speed signal;
•
the Brake Board is not generating current;
•
the brake is defective.
Does the Brake Board supply
tension at the brake?
THERE IS NO
RESISTANCE
Are the Watt and SPM values
shown on the display different
from zero?
NO
YES
1
Carry out the "The speed
signal is incorrect"
troubleshooting procedure
Replace the Brake Board
YES
Is there the tension to the input
of the brake?
NO
Replace the Brake
YES
Replace
connecting cable
NO
3
YES
Is the resistance on the Brake
winding more or less 5 Ohm?
Replace the Brake
NO
2
SEL
F
-PO
W
ER
ED
Summary of Contents for SYNCHRO Excite +
Page 1: ...S Sy yn nc ch hr ro o E X C I T E REV 7 1 ...
Page 2: ......
Page 4: ......
Page 10: ...SYNCHRO Excite Service maintenance manual rev 7 1 Page vi Page intentionally left blank ...
Page 50: ...SYNCHRO Excite Service maintenance manual rev 7 1 Page 3 18 Page intentionally left blank ...
Page 98: ...SYNCHRO Excite Service maintenance manual rev 7 1 Page 6 40 Page intentionally left blank ...
Page 182: ...SYNCHRO Excite Service maintenance manual rev 7 1 Page 9 26 Page intentionally left blank ...
Page 184: ...SYNCHRO Excite Service maintenance manual rev 7 1 Pagina 10 2 Page intentionally left blank ...
Page 195: ......