Issue/Rev. 1.4 (9/18) ║ MNF18001EN / DOK-479-E • Page 91
9.7.1.3.1.1.5. Compartments 1 – Volume Preset – 313215
3132151 – Correction Value
After the delivery, the correction value
for the volume preset is automatically
adjusted. This correction value is
necessary because, after the command
is given to close the valves, a certain
amount of time passes before the flow
is actually stopped. This after run quantity
can be entered in the correction value,
so that the specified preset amount is
achieved with significantly greater
precision.
3132152 – Standard Preset
→
Value in
liters = 5000
9.7.1.3.2. Compartments monitoring during loading – 31351
A setting is made here as to whether the compartment should be monitored during loading.
9.7.1.3.3
.
Compartments monitoring during delivery – 31352
A setting is made here as to whether the compartment should be monitored during delivery.
MultiLevel Instruction Manual
MENU structure
Description
Comment
OFF
No compartment monitoring
Without foot valve
Level monitoring only
FV only at start
Can delay the ‘calming’ of the level,
since air may be in the piping.
Not recommended, unless
expressly desired.
FV only at end
Not recommended, unless
expressly desired.
FV at start and end ATTENTION:
If the foot valves are opened again
shortly before printing the receipt,
residual volumes can lead to the wet
leg sensor being wetted!
Not recommended, unless
expressly desired.
Description
Comment
OFF
No compartment monitoring
Without foot valve
Level monitoring only
PTB requires this setting
FV only at start
Can delay the ‘calming’ of the level,
since air may be in the piping.
Not recommended, unless
expressly desired.
FV only at end
ATTENTION:
If the foot valves are opened again
shortly before printing the receipt,
residual volumes can lead to the wet
leg sensor being wetted!
Not recommended, unless
expressly desired.
FV at start and end ATTENTION:
If the foot valves are opened again
shortly before printing the receipt,
residual volumes can lead to the wet
leg sensor being wetted!
Not recommended, unless
expressly desired.
Summary of Contents for Sening MultiLevel
Page 6: ...Page 6 MNF18001EN DOK 479 E Issue Rev 1 4 9 18 Page intentionally left blank ...
Page 22: ...Page 22 MNF18001EN DOK 479 E Issue Rev 1 4 9 18 Page intentionally left blank ...
Page 36: ...Page 36 MNF18001EN DOK 479 E Issue Rev 1 4 9 18 Page intentionally left blank ...
Page 52: ...Page 52 MNF18001EN DOK 479 E Issue Rev 1 4 9 18 Page intentionally left blank ...
Page 131: ...Issue Rev 1 4 9 18 MNF18001EN DOK 479 E Page 131 MultiLevel Instruction Manual Form Layout ...
Page 138: ...Page 138 MNF18001EN DOK 479 E Issue Rev 1 4 9 18 Page intentionally left blank ...
Page 168: ...Page 168 MNF18001EN DOK 479 E Issue Rev 1 4 9 18 Page intentionally left blank ...