Page 84 • MNF18001EN / DOK-479-E ║ Issue/Rev. 1.4 (9/18)
3132132 – Pipe Volume
The volume of the pipe between the foot
valve and the line valve is entered here.
This parameter is entered automatically
during the data transmission from the
calibration system to the MultiLevel. As
a rule it no longer needs to be changed
by hand.
→ value in mL = 1/1000L
Figure 42:
Pipe Volume
3132133 – Residual Volume
The entire residual volume that can no
longer be measured by the level sensor
(including the pipe volume)
is entered
here. This parameter is entered
automatically during the data
transmission from the calibration
system to the MultiLevel. As a rule
it no longer needs to be changed
by hand.
→ value in
mL = 1/1000L
Figure 43:
Residual Volume
3132134 – Float MIN
Fill level or minimum float position below which the measurement of the residual
volume begins and the fill volume is no longer determined in relation to the fill
height.
→ value in
1/1000 mm
→ specified:
40000 μm = 40mm
(Deviations permitted only in special cases and only on consultation with
TechnipFMC)
3132135 – Float MAX
Max. fill level that should be reached when calibrating the compartment. This
value serves to avoid overfilling during calibration by automatically switching off
the pump when the value is exceeded. The value must be determined manually
before calibration.
ATTENTION:
• The value is valid only for the compartment that is being calibrated and not
for compartments that serve as storage tanks during calibration!
• The value is of no importance during operation and does not replace any
overfill protection functions!!
→ value in 1/1000 mm
→ Can be read off from the help display on the delivery screen or from the
loading screen, if no calibration has been performed yet and height values are
displayed.
MultiLevel Instruction Manual
MENU structure
Summary of Contents for Sening MultiLevel
Page 6: ...Page 6 MNF18001EN DOK 479 E Issue Rev 1 4 9 18 Page intentionally left blank ...
Page 22: ...Page 22 MNF18001EN DOK 479 E Issue Rev 1 4 9 18 Page intentionally left blank ...
Page 36: ...Page 36 MNF18001EN DOK 479 E Issue Rev 1 4 9 18 Page intentionally left blank ...
Page 52: ...Page 52 MNF18001EN DOK 479 E Issue Rev 1 4 9 18 Page intentionally left blank ...
Page 131: ...Issue Rev 1 4 9 18 MNF18001EN DOK 479 E Page 131 MultiLevel Instruction Manual Form Layout ...
Page 138: ...Page 138 MNF18001EN DOK 479 E Issue Rev 1 4 9 18 Page intentionally left blank ...
Page 168: ...Page 168 MNF18001EN DOK 479 E Issue Rev 1 4 9 18 Page intentionally left blank ...