b) Category HIGH, steady failure or high category failure
(no reset possible by FADEC-Test Knob)
- Engine Speed max. tolerated difference ECU A/B ...... Exceeded
- Injector ................................................................................. Error
- Injector or InjectorPower........................................... Overcurrent
- Mapping ........................................................................... Corrupt
- Old version Table.................................................... Programmed
- Sensor Load ..................................................................... Broken
- Sensor IV-......................................................................... Broken
- Sensor IV+ ........................................................................ Broken
- Valve or ValvePower ................................................ Overcurrent
- Watchdog............................................................................ Reset
- 50V Power ................................................................ Overvoltage
4.5
Takeoff and Climb
•
Quickly move the load selector to the full-load position.
4.6
During Flight
•
Constantly monitor whether the oil pressure, oil
temperature and coolant temperature is within the operation
limits (refer to Chapter 3, Section 3.4, Page 2 of this Manual
for these values).
•
Monitor the fuel temperature in the tank
(refer to Chapter 3, Section 3.4, Page 2 of this Manual for
these values).
•
Monitor the FADEC warning lights.
4.7
Shutting Down the Engine
1.
Load selector -
"IDLE"
2.
All electrical consumers -
"OFF"
3.
Engine Master switch -
"OFF"
4.
Main Bus switch -
"OFF"
Note:
If the oil and / or water temperature approach their respective
upper limits during the climb, reduce the angle of climb for a
better cooling, if possible.