Operation & Maintenance Manual
CD-135 / CD-155
OM-02-02
Revision no.:
Revision date:
Chapter:
Issue:
Issue date:
Page:
Content:
02-OM-06-02
4
30.07.2014
31
74
7
20.07.2016
4.
Attach the new aluminum sealing ring to the filter cap.
See Fig. 6.19.
5.
Remount the filter cap and tighten it to the specified
tightening torque.
Tightening Torque:
55 Nm
6.
Preset the proportional pressure reducing valve. Refer to
Chapter 72-10.05 of RM-02-02.
7.
Secure the gearbox oil filter cap with a locking wire.
See Fig. 6.20.
8.
Do an Engine Test run according to Annex 4 of this Chapter.
9.
Do a visual inspection and a check for leaks.
10.
Check the gearbox oil level according to Annex 9 of this
Chapter.
Note:
Make sure that the spring in the filter cap is fixed.
Fig. 6.20
Lock wiring the oil filter cap, the proportional pressure
reducing