6.
Clearing Diagnostic Warnings
Should the diagnostic warning lights be active, they must be
cleared after the discrepancy has been diagnosed and
resolved before the aircraft can be released for service.
a) Menu FADEC => Clear Warnings. The following
screens will appear:
Fig. 6.38
FADEC read-out - Clear warnings
Fig. 6.39
FADEC read-out - Enter password