Operation & Maintenance Manual
CD-135 / CD-155
OM-02-02
Chapter:
Issue:
Issue date:
Page:
Content:
02-OM-06-02
4
30.07.2014
38
74
Revision no.:
Revision date:
7
20.07.2016
Annex 10
FADEC Read-out
1.
General
The FADEC service tool is designed to provide the user
access to Real time data, the onboard logger system as well
as the event log information available from the Technify
Motors GmbH FADEC system, and to facilitate organizing
the data and to send this data to Technify Motors GmbH.
The tool is a requirement for standard maintenance as well
as troubleshooting of the powerplant. This document
provides instructions for using the software. Consult the
operation & maintenance manual, the fault isolation manual
as well as other available documentation for instructions
and limitations of operation, maintenance, repair and
troubleshooting. Routine maintenance must consist of a
regular maintenance download and include:
•
Event Log (FADEC DATA)
•
Real Time Log File from Ground Run
(refer to Chapter 4, Section 4.4.2, Page 5 of this
Manual for ground run procedures and requirements)
and shall be sent to:
[email protected]
Request for diagnosis must consist of an extended
download and must include all of the above plus
•
download of the onboard logger (both ECUs),
•
a detailed description of the abnormality.
and shall be sent to
The software tool is capable of providing the appropriate
download in a single operation to reduce time and effort
spent by the user. Please proceed to section 4 or 5 of this
annex, as appropriate to perform a regular maintenance or
an extended download.