7-2
7. WIRELESS LAN PARAMETER SETTING
EO18-33014
4. By following the messages on the screen, perform the installation.
5. When the installation was completed successfully, the end screen appears. Click on the [Finish] button to
end the installation.
7.1.3 Parameter Setting Procedure (when using TEC Protocol)
When using the TEC Protocol, ACTiSYS ACT- (IrDA Com-Port Serial Adapter) is required.
1.Connect the ACT- to the serial port of the PC.
Example
(Revision Date: Jan. 29, 2004)
7.1 WHEN USING THE RFLAN CONFIGURATION TOOL
ACT-IR220+
PC
2. Confirm the IrDA settings of the printer in the following way.
Turn on the printer while pressing and holding the [FEED] key on the printer to start the printer in the system
mode. Hold the [FEED] key until the indicator LED starts to blink in green. Since a diagnostic test result is
automatically printed, confirm that the settings fo the IrDA interface are "TEC 19200".
NOTE:
Do not press the [FEED] key after the diagnostic test printing. Doing so causes the printer to enter
another mode where printer parameters cannot be set.