2-28
2. MAIN UNIT REPLACEMENT
EO18-33014
2) Adjusting reflective sensor
Place the label part of the specified paper on the reflective sensor, then press the [F4] key of the keyboard,
or click on the [F4: Reflective sensor] button on the screen. The reflective sensor will be adjusted. When
the adjustment is completed, all of the current sensor A/D values will be displayed.
NOTE:
If the adjustment value of the reflective sensor is out of the judgement criterion, an error message
will appear. When clicking on the OK button of the error message window, the A/D values will be
displayed. In this case, however, an "Error" is shown in place of the A/D value for the reflective
sensor. Readjust the reflective sensor.
3) Adjusting transmissive/strip sensors
Remove labels from the backing paper of the specified paper, then place only the backing paper on the
transmissive sensor. Pass the backing paper through the path for the strip issues.
Press the [F5] key of the keyboard, or click on the [F5: Transmissive/Strip sensor] button on the screen.
The transmissive and strip sensors will be adjusted. When the adjustments are completed, all of the
current sensor A/D values will be displayed.
NOTE:
If the adjustment values of the transmissive/strip sensors are out of the judgement criterion, an
error message will appear. When clicking on the OK button of the error message window, the
A/D values will be displayed. In this case, however, an "Error" is shown in place of the A/D
values for the transmissive and strip sensors. Readjust these sensors.
(Revision Date: Jan. 29, 2004)
2.7 SETTING AND ADJUSTMENT