Maintenance of the FDD should be done on a clean bench at room
temperature and humidity.
It is recommended to execute the check and
adjustment of the track alignment after leaving the FDD for at least
2 hours at room temperature and humidity.
The magnetic head, disk,
steel belt, etc. might suffer from dust and dirt if the maintenance is
not undertaken in a clean environment.
(6 ) Orientation of the FDD
Position the FDD as shown in Fig.410 unless otherwise specified.
Horizontal and vertical orientations with lever side up should be used.
Horizontal setting
Lever
Vertical setting
(Fig.410) General orientation of the FDD during maintenance
(7) Head load of the CSS model
For the CSS model (without head load solenoid)., the FDD is always in
head load condition as far as a disk is inserted and the front lever
is closed.
(8) Work disk
When you use the SKA, use a soft sectored disk.
(9) Disks for high density FDD (FD-55G)
4036
Summary of Contents for FD-55 Series
Page 7: ...SECTION 3 THEORY OF OPERATION 300...
Page 8: ...3 1 CONSTRUCTION AND FUNCTION 3 1 1 General Block Diagram Fig 301 General block diagram 301...
Page 23: ...Fig 308 Control circuit block diagram 316...
Page 40: ...SECTION 4 MAINTENANCE 4000...
Page 56: ...J4 J12 Option J9 J5 Top view of the FDD Fig 401 Types of connectors 4016...
Page 95: ...Note Refer to item 4 2 1 as to handling of the set screw 4057...
Page 102: ...k Key in Cl SET TMAX L Confirm as in item j 4064...
Page 104: ...Notch B position TP6 voltage 0 5V Max LED indicator Fig 422 Check of file protect sensor 4066...
Page 125: ...k Eject the level disk and release the Invert and ADD modes of the oscilloscope 4087...
Page 136: ...Fig 431 Adjustment track alignment 4098...
Page 153: ...Fig 436 Adjustment of index sensor 4115...
Page 172: ...Fig 440 Replacement of head pad 4134...
Page 176: ...Plate Fig 441 CSS Ass y and shift lever position 4138...
Page 177: ...SECTION 5 DRAWINGS PARTS LIST 500...
Page 179: ...r Fig 501 External view No l 502...
Page 181: ...PCBA DD motor servo Fig 503 External view No 3...
Page 182: ...Fig 504 External view No 4 505...
Page 183: ...Partis nrnnber of the FDD Fig 505 Extemal view No 5 506...
Page 188: ...Fig 506 Mechanical section break down 511...
Page 199: ...PCBA DD MOTOR SERVO PARTS LOCATION Type S i 522A...
Page 200: ...PCBA DD TOR SERVO PARTS LOCATION Type TO 522B...
Page 201: ...PCBA DD MOTOR SERVO PARTS LOCATION Type G 522C...
Page 202: ...PCBA DD MOTOR SERVO PARTS LOCATION Type T 522D...
Page 204: ...523B PCBA DO MOTOR SERVO SCHEMATIC Type K...
Page 205: ...o 523C i 1 PACB DD HOTOR SERVO SCHEMATIC Type G...
Page 206: ...CV 5 3 3 H 2SV 523D PC DD M o t o r SERVO SCHEMATIC Type T...
Page 207: ...PCBA MFD CONTROL B PARTS LOCATION PCB ISSUE A G 524A...
Page 208: ......
Page 209: ...PCBA FRONT OPT PARTS LOCATION 525 PO I...
Page 210: ......
Page 211: ......
Page 212: ......
Page 213: ......
Page 214: ......
Page 215: ......
Page 216: ......