62
SECTION 3
INSTALLATION
Upon receipt of the filter, unpack it and carefully inspect for any damage sustained in transit. If damage is
apparent, the freight or express agent should be notified within 15 days of receipt of the product and a
request be made that he make inspection of the
merchandise; then a claim should be filed against the
carrier. For UPS shipment damage, save the box and
packing material and contact TB Wood’s Incorporated
immediately.
TB Wood’s WLF Series line filters are designed to
mount directly to a flat surface such as an enclosure
panel. Metal hardware should be used to assure that
the case of the filter is at earth ground potential. The
filters can be mounted parallel to the panel or
perpendicular to the panel.
The filter should be installed as close as possible to
the inverter. When mounting the filters parallel to the
panel, the inverter can be mounted to the top of the
filter module with the hardware provided (see figure
1).
Dimensions
(IP20 versions
to 20HP)
Case Dimensions
Case Mounting
Drive Mounting
Terminals
Model
L
W
H
X
Y
Size
DL
DW
Size
Lines
GND
WLF40050H 14.17/360
8.74/222
1.97/50 13.46/342
6.30/160
M6 11.02/280 7.87/200
M6
AWG 6
M5
WLF40200H 19.69/498
9.13/232
1.97/50 18.82/487
7.09/180
M6 16.50/419 7.87/200
M6
AWG 6
M5
Notes:
1. Dimensions in inches/millimeters
2. Terminal Labeled GND is at earth potential (PE)
Figure 1
Figure 2
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Summary of Contents for WFC1000 Series
Page 3: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 5: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 77: ...69 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 80: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...