3
Model Series
WFC1000
WFC2000
WFC4000
Torque Limit Deceleration
Programmable – 0.1 to 30 Seconds
29
Rate
Minimum Frequency in
Programmable – 0.5 to 400 Hz
29
Torque Limit
Torque Boost
Programmable to suit requirements plus Autoboost
30
Dynamic Braking
30-200% of drive rating (10 sec. max.) standard
–
Consult factory for model specific data.
Additional capacity available by adding external DB kits.
Adjustments
Over 100 parameters can be monitored with
–
over 80 user adjustments
PWM Frequencies
Two settings available
39
Agency Listing
UL
®
and cUL
®
Listed; CE Marked
–
Charge Indicator
Indicates the presence of potentially lethal bus voltage
15
Ground Fault
All models fully protected
–
Output Short Circuit
All models fully protected
–
(Line-to-Line)
Electronic Motor Overload
Programmable Inverse Time Overload Trip
32, 33
Overvoltage Trip Level
407 VDC
815 VDC
–
(on DC bus)
Undervoltage Trip Level
180 VDC
400 VDC
–
(on DC bus)
Torque Limit
4 Quadrant – Independently Programmable
28, 31
Program Lockout
User definable security access code
42
Line Start Lockout
Prevents automatic startup when line power
39
is applied (defeatable by programming)
Overtemperature
Drive will shut down if heat sink temperature
–
exceeds rating
DB Failure
Drive will sense circuit failure and shut down
–
Error/Fault Messages
19 fault codes
53
6 warning displays
Fault Storage
Last three (3) faults stored. Most recent displayed.
25
Line Transient Limit
2 KV. Maximum (less than 40 microsecond duration)
–
External MOL Contact
Compatible with NC fault contact
17
Operating Controls
1. Keypad: Forward, Reverse, Jog, Stop, Program,
18
Shift, Enter, Local/Remote and Up/Down Arrows.
2. Terminal strip: See typical connection
16
diagrams or consult factory.
3. RS485 Serial Input/Output (SIO) Link.
43
LED Indicators
Forward, Reverse, Jog, Stop, Bus Charged
20
and CPU Active
Display
2 – lines of 16 characters, Back-Lit
alphanumeric for all modes of operation.
Programmable to display in English, French,
21, 40
Spanish or German.
Any engineering units such as RPM, FPM, &
GPM are supported.
Auxiliary Relay
Programmed as Fault Relay. Can be
17, 34
programmed to signal one of eleven conditions
See
Page
Control
Specifications
(continued)
Protection
Features
Operating
Features
TABLE 1.4 (Con’t.)
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Summary of Contents for WFC1000 Series
Page 3: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 5: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 77: ...69 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 80: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...