When the programming mode is accessed by pressing the PROG
key for LEVEL 1 or SHIFT and PROG keys for LEVEL 2 or 3, the
display to the right will appear for one second.
RIGHTS
This section explains the operator’s access rights after the
program mode has been entered:
PROGRAM
This indicates that while in the programming
mode parameter data can be changed.
VIEW
If the inverter is in the run mode (forward or reverse) when the PROG key was pressed,
parameters may be viewed but not changed.
ACCESS
This denotes the access level that is being entered. It may show Level 1 or Level 2 (Section 4) or Level 3
(Section 5).
Once the program mode has been accessed, the
display shown to the right will provide information on
each parameter:
DESCRIPTION
The top line will give a full 16 character description of
the parameter that is being accessed.
RIGHTS
The first four characters of the second line will indicate if the particular parameter can be changed (PROG) or
only examined (VIEW). If an attempt is made to change data while in the VIEW mode, the message **NO
ACCESS** will be displayed for one second.
PARAMETER
This is the actual parameter number being displayed. When data is being changed, this number will blink on
and off. See inside the front cover for a listing of all Level 1 and Level 2 parameters.
DATA
Up to eight characters are used to display the information stored in the parameter. Some parameters have a
unit designator such as:
s
– Seconds
h – Hours
C – Degrees centigrade
Hz – Hertz
% – Percent
A – Amperes
When the inverter stops due to a fault trip, a unique
error message will be displayed along with a flashing
STOP LED indicator. Two “pages” of information are
available concerning the actual fault and drive
status. Page one is shown at right.
CODE
The top line signifies that a fault has occurred and
displays one of 19 fault codes. See Section 7 –
Troubleshooting for a complete list of all codes and explanations of each.
NEXT PAGE
The “^” symbol indicates that pressing the Up Arrow will shift the display to Page 2.
DESCRIPTION
The second line provides a full 16 character description of the cause of the fault.
Page 2 of the fault display will show the operating conditions of
the inverter at the time of the fault. All other operating parameters
are “frozen” until the drive is reset.
PA R A M E T E R S
P RO G R A M
L E V E L 1
PROGRAMMING ACCESS
Access
Rights
M I N F R E QU E N C Y
P RO G 3 1 :
0 . 0 H z
PROGRAMMING DISPLAYS
Data
Rights
Parameter
Description
FAU LT F 0 7
^
M O L C O N TAC T O P E N
FAULT DISPLAY – PAGE 1
Description
Next Page
Code
AT S P E E D
F W D
4 9 . 6 0 H z
8 0 %
FAULT DISPLAY – PAGE 2
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Summary of Contents for WFC1000 Series
Page 3: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 5: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 77: ...69 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 80: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...