TATSUNO EUROPE a.s., www.tatsuno‐europe.com
14
Table 8 ‐ Description of values of P05 parameter
Parameter Meaning
P05‐1
Version of program's metrology parts
P05‐2
Metrology check sum of the program
P05‐3
Release number (C + number), program version
P05‐4
Total check sum of the program
P05‐5
Check sum of the parameter memory
P05‐6
Check sum of the device for temperature compensation
P05‐7
Time and date of program creation (e.g. 07:56:17, 19. 07. 2011)
2.1.9.
HISTORY OF ERROR MESSAGES (CODE P06)
This function is intended to show history of last 100 error codes of defect in the order in which they occurred in
the dispenser.
After switching to the P06 parameter the display shows the code of the last error message (e.g. 30 – E30 zero
fuel unit price). After pressing the
<ENT>
key the display shows time and date of defect occurrence (12:45:10,
31.12.2016 shown in the figure). After pressing the
<+>
key the display shows the code of the last but one error
message on the given side of the dispenser (18 – E18 loss of communication with the payment terminal), see
Table 9.
Table 9 ‐ History of error messages P06
Parameter Meaning
P6‐00
code of the last dispenser error (the latests)
P6‐01
code of the last but one dispenser error
…
…
P6‐98
code of the 99th dispenser error in the order
P6‐99
code of the 100th dispenser error in the order (the oldest)
NOTE
If two errors of the same type with the same error code occur in sequence, only one ‐ the latest ‐ error will
be stored in the counter memory (there may not be two or more same errors stored in sequence).
Err
30
€
Kg
€/kg
P6-00
124510
3111216
€
Kg
€/kg
P6-00
ENT
ENT
Err
30
€
Kg
€/kg
P6-00
Err
18
€
Kg
€/kg
P6-01
+
‐