background image

Installation, Operation and Maintenance Manual

QT

TM

 Cube Max

TM

 Models:

QTCBMX-1S-1M, QTCBMX-2S-1M,  

QTCBMX-3S-1M, QTCBMX-4S-1M,  

QTCBMX-1L-1M, QTCBMX-2L-1M,  

QTCBMX-3L-1M, QTCBMX-4L-1M,  

QTCBMX-5L-1M, QTCBMX-1L-.5M,  

QTCBMX-2L-.5M, QTCBMX-3L-.5M

IOM-HS-QTCubeMax

Table of Contents

System Specifications  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2
Replacement Filters  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2 
Notice to Installers  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2 
Installation Precautions   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3 
Operation   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3 
Installation  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3 
Maintenance   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3 
Filter Cartridge Replacement Procedure   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3 
Replacement Parts List   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 4 
System Drawings   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 4 
Limited Warranty  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 8

QTCBMX-4L-1M

Tested and certified by WQA against NSF/ANSI Standard 

42 for the reduction of claims specified on the performance 

data sheet & NSF/ANSI 372 for "lead free" compliance .

Cube Max Models QTCBMX-1L- .5M, QTCBMX-2L- .5M 

and QTCBMX-3L- .5M are tested and certified by WQA 

against NSF/ANSI Standard 42 for Material Safety and 

Structural Integrity, and NSF/ANSI Standard 372 for "lead 

free" compliance .

Read this Manual BEFORE using this equipment.
Failure to read and follow all safety and use information 

can result in death, serious personal injury, property 

damage, or damage to the equipment.
Keep this Manual for future reference.

You are required to consult the local building and plumbing 

codes prior to installation.  If the information in this manual 

is not consistent with local building or plumbing codes, 

the local codes should be followed. Inquire with governing 

authorities for additional local requirements.

WARNING

!

WARNING

!

Do not use with water that is microbiologically unsafe or of 

unknown quality without adequate disinfection before or after the 

system .

WARNING

!

Summary of Contents for QTCBMX-1S-1M

Page 1: ...e Max Models QTCBMX 1L 5M QTCBMX 2L 5M and QTCBMX 3L 5M are tested and certified by WQA against NSF ANSI Standard 42 for Material Safety and Structural Integrity and NSF ANSI Standard 372 for lead free compliance Read this Manual BEFORE using this equipment Failure to read and follow all safety and use information can result in death serious personal injury property damage or damage to the equipme...

Page 2: ...icron Carbon Block with Phosphate Scale Control QTCBMX 2L 1M HSR L SED 5M 6 Months 20 5 Micron Sediment Pre Filter QTCM20 6 Months 20 QT 0 5 Micron Carbon Block with Phosphate Scale Control QTCBMX 3L 1M HSR L SED 5M 6 Months 20 5 Micron Sediment Pre Filter QTCM20 6 Months 20 QT 0 5 Micron Carbon Block with Phosphate Scale Control 2 QTCBMX 4L 1M HSR L SED 5M 6 Months 20 5 Micron Sediment Pre Filter...

Page 3: ...n gauges into their connection ports Do not twist on gauge case 3 Install the filters into the filter manifold Make sure all plastic wrapping and protective plastic caps have been removed from the filters prior to their installation Insert the prefilter into its blue canister Make sure the blue canister s oring is properly inserted into its oring groove Thread the housing onto the head with standa...

Page 4: ...t valve to the full open position Allow water to flush to drain for 5 minutes 9 Slowly close the drain valve and check the system for leaks 10 Slowly open the outlet valve to restore water flow to downstream equipment 11 Record filter change date in system maintenance log Teflon is a registered trademark of E I DuPont de Nemours Company Replacement Parts Description Ordering Code Filter Head 3 8 T...

Page 5: ...5 QTCBMX 2S 1M QTCBMX 2L 1M QTCBMX 3S 1M QTCBMX 3L 1M QTCBMX 2L 5M 25 51 14 69 5 56 25 70 15 73 5 56 26 08 15 73 5 56 QTCBMX 3L 5M 25 51 19 44 5 56 25 70 20 30 5 56 26 08 20 30 5 56 ...

Page 6: ...QTCBMX 4S 1M QTCBMX 4L 1M QTCBMX 5L 1M 25 70 24 73 5 56 26 08 24 73 5 56 26 08 29 23 5 56 Allow 3 76mm of clearance at bottom of system for removal of filter bowls for filter cartridge replacement NOTICE ...

Page 7: ...7 Notes ...

Page 8: ...any incidental special or consequential damages including without limitation lost profits or the cost of repairing or replacing other property which is damaged if this product does not work properly other costs resulting from labor charges delays vandalism negligence fouling caused by foreign material damage from adverse water conditions chemical or any other circumstances over which the Company h...

Reviews: