The setting mode is started by pressing the <M> button – Manager mode, or <A> button – Attendant
mode. The set and read values are displayed directly on the dispenser display.
NOTE
In addition to setting and reading values it is possible to use A1, A2, L1, L2 and CLEAR keys to set presets
on the dispenser. The <0> key may be used to unblock the dispenser after error or in the operating mode with
blocking after delivery.
All data is displayed on the dispenser display in setting
modes. While controlling using the remote controller the
data is displayed on the display of that side where the
setting mode was called up from by the remote controller.
Individual parameters are shown as follows on the display:
No. of parameter:
P01
Item No.:
1 (e.g. delivery hose number)
Parameter value:
1234567890 (amount in grams)
2.1.2.
ATTENDANT MODE
The Attendant mode is started by pointing the IR remote controller at the dispenser display (from the
distance of approx. 1m from the dispenser display centre) and pressing the <
A
> button.
All delivery
nozzles on the dispenser must be hung in advance and the sale on the dispenser must be finished (paid).
After calling up the Attendant mode the value of the first parameter P01 is displayed. Parameters and
their items may be switched by using the <
>
> and <
+
> keys (see Figure 3).
The Attendant mode allows to view
but not change
the values of all parameters listed below ‐ see Table
2.
Table 2 ‐ List of parameters for setting in the Attendant mode
Parameter Description
01
Non‐resettable amount totalizers
02
Daily amount totalizers (resettable)
03
Product unit prices (in manual mode)
04
Current time and date
05
Counter program version and check sums
06
Error message history
07
Latest delivery history
Individual parameters will be described in the following section.
The Attendant mode is finished by pressing the <
A
> key. The mode is also finished automatically if no
remote controller button is pressed for 60 seconds.
tot
317890
€
Kg
€/kg
P01-1
Parameter’s number
Item number
Parameter‘s description
Parameter’s value