DISPENSER SETTING AND BASIC FUNCTIONS
Dispenser setting is performed by the set of setting parameters via witch it is possible to control functional
parameters of the dispenser, totally change the mode and behaviour of the dispenser in different
situations. The parameter values can be viewed and changed using the remote IR (infrared) controller,
the service keypad, or the preset keypad buttons located on the dispenser. The basic dispenser control
unit is an electronic counter that is stored with the displaying units inside the lockable counter cabinet in
a non‐explosive zone. Inside CNG dispenser is used exclusively counter type TBELTM.
2.1.
DISPENSER COUNTER TBELTM
The TBELTM electronic counter for dispensers, the manufacturer of which is TATSUNO EUROPE, a.s., is set
by the IR remote controller. The yellow service remote controller PDERT‐5S is intended for service
engineers authorized by the dispenser manufacturer. This remote controller allows to perform complete
settings of all dispenser parameters. The white remote controller PDERT‐5O is intended for fuel station
managers and this remote controller allows them to perform:
reading non‐resettable electronic mass totalizers of all delivery hoses
reading and resetting daily electronic mass and financial totalizers of all hoses
setting of unit prices of products (in manual operation)
reading and setting of operating parameters of the dispenser
The setting mode may be called up at the dispenser by a below stated procedure only in the condition
when the dispenser is at rest ‐ i.e. in the condition of “finished delivery”, all nozzles hung, all sales finished.
There are two access modes:
Attendant mode
which is intended to fuel station attendants – it only allows them to read values of
electronic totalizers and values of dispenser basic parameters. Their values may not be reset or
changed.
Manager mode
which is intended for the fuel station manager – it allows him to read values from
dispensers, reset daily totalizers and set basic operating parameters of the dispenser. The access to
the Manager mode is protected by password.
2.1.1.
DESCRIPTION OF PDERT REMOTE CONTROLLER
The keypad of the remote controller has the following key and arrangement (see Figure 3). While using
the IR remote controller it is necessary to move the remote controller closer to the distance of approx. 1
meter from the centre of the dispenser display ‐ see Figure 2.