CNG dispensers TATSUNO EUROPE ‐ Quick User Guide
25
The LCD display consists of the following parts:
Display segment
Function
Note
Amount delivered
Volume delivered
Delivered fuel unit price
Minimum Measured Quantity
‐ not used for CNG dispensers
Temperature volume compensation
(ATC)
‐ not used for CNG dispensers
High and low output signals (fuel
flow)
‐ not used for CNG dispensers
Function and fault indication of the
vapour recovery system
‐ not used for CNG dispensers
Dispenser status indication ‐ released
for delivery / blocked
‐ it appears automatically when the dispenser status changes
Signalling of forced termination of
delivery
‐ it appears after the STOP command has been received from
the booth, after the preset number / preset amount has been
reached or after the allowed time without delivery has been
exceeded
Fault signalling or maintenance
required.
‐ it will be displayed at each fault indication together with the
fault code
3.4.5.
SWITCHING OFF THE CNG DISPENSER
switch off the CNG dispenser power supply
(electronics power supply) in the fuel station
switchboard;
displaying the “OFF” message on the unit price display
and switching the display illumination off. The last
data is shows on the display for at least 15 minutes
after the power supply disconnection. After elapsing
this period and “erasing” the display the display status
is saved into the counter memory and will be shown after the power supply is connected again – see
the previous section.
Now the dispenser is out of order.
406
.
1
15
.
326
€
Kg
€/kg
OFF