CNG dispensers TATSUNO EUROPE ‐ Quick User Guide
17
controlled by the P03 parameter. If no special manual mode with blocking after delivery or a mode with
RELEASE signal control is set, the delivery starts immediately after lifting the delivery nozzle and
resetting the display.
A detailed description of operating modes is in section
Chyba! Nenalezen zdroj odkazů.
. Setting is made by
pressing the
<Ent>
key and entering the
mode number
(1 or 3) and confirming by the
<Ent>
key.
2.1.15.
ERROR STATISTICS (CODE 13)
This function is intended for showing statistics of errors (defects) occurred on the dispenser from the moment
of initialization or resetting the counter. This parameter has different arrangement of data on the display:
The first line of the display shows the dispenser error code
(E30), the second line shows frequency of error occurrence
from dispenser commissioning or from resetting the
statistics by the service engineer (2x).
You can browse the error statistics by using
<+>
or
<‐>
keys.
2.1.16.
CURRENT OPERATING TEMPERATURE (CODE 14)
This function shows current operating temperature measured by the heat sensor located on the processor
board of the counter, possibly a current temperature of the heat sensor Pt100 located in the dispenser pressure
module.
This parameter has the following arrangement of data on the
display:
The first line of the display shows the temperature on the
processor unit of the counter in tenths of Celsius degrees
(26°C). The second line shows an average ambient
temperature in the dispenser pressure module in tenths of
Celsius degrees (25.9°C).
2.1.17.
RESETTING DAILY TOTALIZERS (CODE 15)
This function is intended for resetting all daily totalizers of delivery hoses/nozzles.
After setting the parameter to
1
and confirming (
<ENT> + <1> + <ENT>
) all totalizers that are a part of the P02
parameter will be
reset
.
Err 30
2
€
Kg
€/kg
P13
26 C
259 C
€
Kg
€/kg
P14