background image

IOM-WQ-LC-100

Installation, Operation and Maintenance

1" Commercial Water Softeners

Series: LC-100

LC-100 Simplex Systems

Summary of Contents for LC-100 Series

Page 1: ...IOM WQ LC 100 Installation Operation and Maintenance 1 Commercial Water Softeners Series LC 100 LC 100 Simplex Systems ...

Page 2: ...uality components Simple programming corrosion resistant mineral tank s and an easy to service design ensures this system will be durable and easy to maintain Thank You The Watts Team Softened water provides a wide variety of benefits such as reducing the potential of lime scale formation in boilers water heaters and heat exchangers to protecting the remainder of the plumbing system from costly ma...

Page 3: ...erheating of electronics may occur and ultraviolet rays from the sun may cause damage Operating ambient temperature 34 to 100 F 1 to 43 C Operating water pressure range 25 to 125psi 171 kPa to 8 6 bar All plumbing connections to the system should be made using industry accepted best practices Plumbing tape or paste may be used on metal inlet and outlet plumbing connections Do not use paste type pi...

Page 4: ...e in soap and cleaning product usage Ion exchange water softening is a process where an ion exchange resin is used to effectively exchange calcium and magnesium hardness cations for sodium cations in the water New or freshly regenerated ion exchange resin is saturated with sodium cations As calcium and magnesium hardness cations come in contact with the ion exchange resin they attach to the resin ...

Page 5: ...eneration B System 7 2 Mineral Tanks 1 Meter Immediate Regeneration C System 14 2 8 Mineral Tanks 2 8 Meters Immediate Regeneration Progressive Flow Tank Staging GPM Threshold for Progressive Feature ________________________________________________ D _____________________________Other System Description 3 Controller Program Settings A Backwash ____________________________________ Minutes B Brine a...

Page 6: ...4 141 8 359 141 8 359 18 457 40 1016 240 109 M4046B SE 663 4 1695 801 2 2045 801 2 2045 161 8 409 161 8 409 18 457 40 1016 320 145 Specifications MINERAL TANK BRINE TANK SOFTENING LBS SALT PER FLOW RATE PRESSURE MODEL NO TANK RESIN GRAVEL TANK SALT CAPACITY REGENERATION SERV DROP BKW SIZE Ft3 SIZE FILL MAX MIN MAX MIN GPM PSI GPM M4032B 275NT 9 x 48 1 0 10 lbs 18 x 40 400 30 K 20 K 15 6 9 15 15 25...

Page 7: ...IZE REQUIRED WEIGHT D x W x H LBS KGS M4032B 275NT 68105378 1 Cubic Foot Simplex Softener with Flow Meter 1 18 x 32 x 64 116 53 M4036B 275NT 68105379 1 5 Cubic Foot Simplex Softener with Flow Meter 1 18 x 33 x 71 136 62 M4040B 275NT 68105381 2 Cubic Foot Simplex Softener with Flow Meter 1 18 x 35 x 69 196 89 M4042B 275NT 68105386 3 Cubic Foot Simplex Softener with Flow Meter 1 18 x 40 x 82 240 109...

Page 8: ...et Up Unpack system and make sure all components are accounted for according to the diagram below according to your specific series number If any components are missing or damaged contact your Watts representative If they can not be reached contact Watts customer service at 800 659 8400 Drain line flow controllers may come factory assembled on control valve s drain port depending on size Distribut...

Page 9: ...into the mineral tank and center it in the bottom The top of the distributor tube should be flush with the top of the tank Test the tape cap to make sure it can not come off during the media loading process 4d Make sure the plastic and tape cap is secure to the top of the distributor tube place a funnel on the top of the tank and load first the gravel then the softening resin into the tank The cap...

Page 10: ...the control valve controller Connect wires into the P2PWR port for SXT controller See page 14 for location and P14 port for NXT2 controller See page 13 for location 18 If applicable install a metal bonding strap across metal inlet and outlet plumbing lines to maintain electrical continuity The system is now ready for Start Up WARNING Operating a system without a drain line flow controller will cau...

Page 11: ...and local codes Do not construct drain line to elevations that exceed 4 feet above the control valve s drain port 11 The full weight of the piping and valves must be supported by pipe hangers or other means 12 Inlet and outlet headers need to be sized according to flow rate requirements by others 13 Power requirements 115v 60hz 2 7 amps per control valve unless otherwise specified 14 Brine tank mu...

Page 12: ...ess Meter Cable Power Supply 3150 3900 Valves Wire Harness Meter Cable Power Supply Communication Cables Hinge Mount mount per valve model noted 44404 Rev A 44403 Rev A LC 100 Systems use 2750 Type Control Valves Network Communication Cables and Connections Use a shielded CAT5 Network Communication cable Connect the network communication cable first before programming Cable length between timers u...

Page 13: ...13 Wiring Diagram NXT2 44403 Rev A Wiring diagrams are reference only All wiring should be done by a certified electrician and meet all electrical codes ...

Page 14: ...14 Wiring Diagram SXT ...

Page 15: ...e In Service Flashing Blue Regeneration Queued Green Regeneration Flashing Green Standby Red Error condition present Two Programmable Auxiliary relay outputs Time based Volume based Chemical pump Alarm based Cycle based Standby Remote input Remote Lockout Remote Regeneration Easy installation with plug in wiring harnesses Assistance Name and Phone Number contact fields Error Log History Water Usag...

Page 16: ...16 NXT2 Controller Display ...

Page 17: ...al regeneration If regeneration occurs for any reason prior to the delayed regeneration time the manual regeneration request shall be cleared Pressing the Extra Cycle button while in regeneration will cause the upper drive to advance to the next step immediately Controller Operation During Regeneration In the Regeneration Cycle step display the controller shows the current regeneration cycle name ...

Page 18: ...Remote Regeneration Ability to trigger a regeneration via a remote input Regeneration Types Softener Filter Meter Delayed When volume remaining reaches zero and the scheduled regeneration time is reached default 2 a m softener 12 a m filter the unit will regenerate Softener Filter Meter Immediate When volume remaining reaches zero the unit will regenerate Time Clock Once volume remaining reached z...

Page 19: ...y on the NXT2 circuit board Activates during selected cycle step Activates upon selected start time Range 0 91 minutes Deactivates upon selected end time Range Start Time plus 1 minute Activates when selected volume gallon is reached Range 0 99999 Selected duration in seconds Range 0 9999 seconds System 8 2 Units Alternating Delayed Immediate Transfer Delayed Regeneration One tank online sup plyin...

Page 20: ...ng certain values may not be able to be viewed or set 7 The controller will display local information not system information 8 In the event of a regeneration occurring while displaying mas ter programming the regeneration step and time remaining will be displayed When regeneration has been completed the display will return to the main screen Example On View settings without the ability to alter se...

Page 21: ...Cycle button to advance to the next value Press the Left button to retreat to the previous value 3 Where applicable use the Up and Down buttons to adjust a value as desired 4 After progressing through all available values the controller will return to Normal operation 5 To exit diagnostic mode progress through all cycles or press hold Left button at any time or simply wait 5 minutes and controller...

Page 22: ...layed When regeneration has been completed the display will return to the main screen Example Real time flow rate reading Example Peak flow since last regeneration Example Gallons at the outlet since installation Example Reserve Capacity setting Example Gallons at the outlet since last regeneration Example Time since last regeneration Example Installed software version Example Total number of rege...

Page 23: ... buttons to adjust as desired 3 Press the Extra Cycle button to advance to the Month field Press the Up or Down buttons to adjust as desired 4 Press the Extra Cycle button to advance to the Calendar Day field Press the Up or Down buttons to adjust as desired 5 Press the Extra Cycle button to return to the normal display screen NOTE Press and hold the Left button to exit without saving NXT2 Time of...

Page 24: ...X X X X X X X X Off Immediate Delayed Auxiliary 1 2 X X X X X X X X X X Off Alarm Based Cycle Based Time Based Lock Window 1 2 X X X X X X X X X X On Off Meter Type X X X X X X X X Paddle 0 75 1 1 5 2 3 Turbine 0 75 1 25 1 5 Generic Continuous Flow Detect X X X X X X X X On Off Save as Non Factory X X X X X X X X X X On Off Lock Settings X X X X X X X X X X Off Delayed Enter Code Time Based Day Ov...

Page 25: ...he display will flash The parameter display will identify the destination cycle step BW BF RR etc and the data display will read Once the valve reaches the cycle step the display will stop flashing and the data display will change to the time remaining During regeneration the user can force the control to advance to the next cycle step immediately by pressing the extra cycle button Setting the Tim...

Page 26: ...control only enters the Program Mode with the valve in ser vice While in the Program Mode the control continues to oper ate normally monitoring water usage and keeping all displays up to date Control programming is stored in memory permanently eliminating the need for battery backup power Manually Initiating a Regeneration To occur that day at the next scheduled regeneration time 1 Press the Extra...

Page 27: ...BF Regen Cycle Step Times The time duration for each regeneration step Adjustable from OFF and 0 199 minutes NOTE If Othr is chosen under Valve Type then R1 R2 R3 etc will be displayed instead D1 D2 D3 D4 D5 D6 D7 Day of Week Settings Regeneration setting On or OFF for each day of the week on day of week systems CD Current Day The current day of the week FM Flow Meter Type All LC 100 systems use a...

Page 28: ...the Extra Cycle button while powering up the unit This resets all of the parameters in the unit Check and verify the choices selected in Master Programming Mode 1 Display Format Display Code DF This is the first screen that appears when entering Master Programming Mode The Display Format setting specifies the unit of measure that will be used for volume and how the control will display the Time of...

Page 29: ...is display to set the Safety Factor and to select the type of reserve to be used in your sys tem This setting is identified by RS in the upper left corner of the screen The reserve selection parameter is only available if the control type has been set to one of the metered options There are three possible settings Abbreviation Parameter SF Safety Factor rc Fixed Reserve Capacity cr Variable Reserv...

Page 30: ...eration cycles are listed in sequence based on the valve type selected for the system and are identified by an abbreviation in the upper left corner of the screen The abbreviations used are listed below Figure 13 Abbreviation Cycle Step BD Brine Draw BF Brine Fill AD Air Draw BW Backwash RR Rapid Rinse SV Service If the system has been configured with the Other valve type the regeneration cycles w...

Page 31: ...18 Relay Setting Display Code RE Press the Extra Cycle button Use this display to enable the relay output This option setting is identified by RE in the upper left corner of the screen Use the Up and Down buttons to enable the relay using either time based tb or flow based Fb Only one method can be used at a time Figure 19 Figure 20 ST Range 0 to total number of cycles minus 1 Figure 21 ET Range S...

Page 32: ...r used by the unit since last installation or last reset SV Software Version Displays the software version installed on the controller NOTE Some items may not be shown depending on control configuration The control will discard any changes and exit the Diagnostics View if a button is not pressed for 60 seconds Figure 25 Figure 26 Figure 27 Diagnostics View Steps 1 Press the Up and Extra Cycle butt...

Page 33: ... identified by RC in the upper left corner of the screen Figure 28 Figure 30 Figure 31 SXT Diagnostics Cont d Figure 29 7 Press the Up button Use this display to view the Total Volume data This option is identified by TV in the upper left corner of the screen 8 Press the Up button Use this display to view the Software Version This option setting is identified by SV in the upper left corner of the ...

Page 34: ...to the resin media Put the other end of the hose inside a water permeable bag and locate the bag over the floor drain 14 Insert a garden hose into the bag side of the poly vinyl hose to fill the hose and PVC pipe with water Air will bubble out of the tank Once all the air is out of the hose and pipe remove the garden hose from the polyvinyl hose to establish a siphon The resin can then be siphoned...

Page 35: ...ADDITIONAL CABLES 3 1 NA DRAIN LINE FLOW CONTROLLER SEE PAGE 41 FOR SELECTION 4 1 68101205 D5036 BELLED DIST TUBE ASSEMBLY FOR 9 12 SOFTENERS 4 1 68101197 D5007 K4 DIST TUBE ASSEMBLY FOR 14 16 SOFTENERS 5 1 68106674 Q9031 TANK ADAPT BUSHING 2 5 X 4 8 THREAD PVC W ORING FOR 14 16 SOFTENERS NOT SHOWN 6 1 68100914 C9084 FIBERGLASS MINERAL TANK 9X48 ALMOND W 2 5 8 TOP 6 1 68100934 C9092 FIBERGLASS MIN...

Page 36: ...D HIGH CAPACITY SAC NA FORM 8 68100354 A7005A MEDIA GRAVEL 20 FLINT 06 X 125 9 1 68102491 G2002BS BRINE TANK ASSY 18X40 BLK W GRID SAFETY FLOAT AIR CHECK FOR 3 8 BRINE HOSE 10 1 68102593 H1018 BRINE OVERFLOW SET 11 1 68102491 G2002B BRINE TANK 18X40 BLK EMPTY 12 1 68102591 H1016 BRINE WELL CAP 4 13 1 68102634 H7007 BRINE SAFETY FLOAT BRINE VALVE AND AIR CHECK ASSY 2310 FOR 3 8 BRINE HOSE 14 1 6810...

Page 37: ...CTRONIC METER CABLE FOR ELECTRONIC METER 16 85 LONG 2 1 68104397 K4519791 02 ELECTRONIC METER CABLE FOR ELECTRONIC METER 35 LONG 2 1 68104398 K4519791 04 EVT ELECTRONIC METER CABLE FOR ELECTRONIC METER 100 00 LONG 2 1 68104399 K4519791 05 ELECTRONIC METER CABLE FOR ELECTRONIC METER 304 00 LONG 3 1 68104471 K4544164 POWER SUPPLY INTL 120V 24V 40VA 4 1 68104575 K4560219 02 ENVIRONMENTAL COVER F 2750...

Page 38: ...38 NXT2 Controller Assembly NXT2 CONTROLLER ASSEMBLY ITEM NO QTY ORDERING CODE DESCRIPTION 1 1 68104777 K4562115 CONTROLLER ASSEMBLY NXT2 1 ...

Page 39: ...39 NXT to NXT2 Conversion Kit NXT TO NXT2 CONVERSION KIT ITEM NO QTY ORDERING CODE DESCRIPTION 1 1 68104778 K4562121 01 CONTROLLER ASSY CONV KIT NXT TO NXT2 W 24V US POWER SUPPLY 1 ...

Page 40: ...40 Replacement Parts SXT Controller Assembly SXT CONTROLLER ASSEMBLY ITEM NO QTY ORDERING CODE DESCRIPTION 1 1 68104457 K4542778 SXT CONTROLLER F 2750 2850 1 ...

Page 41: ... 2 0 GPM 4 1 68104601 K4560365 2 4 DRAIN FLOW CONTROLLER 3 4 F X 1 2 F NPT 2 4 GPM 4 1 68104602 K4560365 3 5 DRAIN FLOW CONTROLLER 3 4 F X 1 2 F NPT 3 5 GPM 4 1 68104603 K4560365 4 0 DRAIN FLOW CONTROLLER 3 4 F X 1 2 F NPT 4 0 GPM 4 1 68104604 K4560365 5 0 DRAIN FLOW CONTROLLER 3 4 F X 1 2 F NPT 5 0 GPM 4 1 68104605 K4560365 7 0 DRAIN FLOW CONTROLLER 3 4 F X 1 2 F NPT 7 0 GPM 5 1 68104072 K4510381...

Page 42: ...SHER 25 GPM 5 1 68104118 K4512095 BRINE FLOW WASHER 50 GPM 5 1 68104119 K4512097 BRINE FLOW WASHER 1 0 GPM 6 1 68104079 K4510913 00 INJECTOR NOZZLE 00 VIOLET 6 1 68104080 K4510913 000 INJECTOR NOZZLE 000 BROWN 6 1 68104081 K4510913 BL INJECTOR NOZZLE 2 BLUE 6 1 68104082 K4510913 G INJECTOR NOZZLE 4 GREEN 6 1 68104083 K4510913 R INJECTOR NOZZLE 0 RED 6 1 68104084 K4510913 W INJECTOR NOZZLE 1 WHITE ...

Page 43: ...K4510913 000 INJECTOR NOZZLE 000 BROWN 5 1 68104081 K4510913 BL INJECTOR NOZZLE 2 BLUE 5 1 68104082 K4510913 G INJECTOR NOZZLE 4 GREEN 5 1 68104083 K4510913 R INJECTOR NOZZLE 0 RED 5 1 68104084 K4510913 W INJECTOR NOZZLE 1 WHITE 5 1 68104085 K4510913 Y INJECTOR NOZZLE 3 YELLOW 6 1 68104086 K4510914 00 INJECTOR THROAT 00 VIOLET 6 1 68104087 K4510914 000 INJECTOR THROAT 000 BROWN 6 1 68104088 K45109...

Page 44: ...TER ASSEMBLY ITEM NO QTY ORDERING CODE DESCRIPTION 1 1 68104734 K4561560 01 METER ASSEMBLY ELECTRONIC TURBINE COMPLETE WITH 1 MNPT PLASTIC 2 2 68104435 K4541241 01 PLUMBING ADAPTOR PLASTIC 1 MNPT 3 2 68110409 41596 PLUMBING ADAPTOR BRASS 1 MNPT 4 2 68110410 41597 PLUMBING ADAPTOR BRASS 1 5 MNPT 2 3 4 1 ...

Page 45: ...EMBLY ITEM NO QTY ORDERING CODES DESCRIPTION 1 1 68104752 K4561932 10 METER ASSEMBLY COMPLETE 1 STAINLESS STEEL MECH ELEC STD RANGE 1 1 68104753 K4561932 11 METER ASSEMBLY COMPLETE 1 STAINLESS STEEL MECH ELEC EXT RANGE 2 1 68110068 K4561936 METER DOME PLASTIC FOR 1 METER W O RING MECH ELEC 2 1 ...

Page 46: ...egeneration Inlet of control plugged due to foreign material broken loose from pipes by recent work done on plumbing system Remove piston and clean control valve Loss of mineral through drain line Air in water system Assure that well system has proper air eliminator control Check for dry well condition Improperly sized drain line flow control Check for proper drain rate Iron in conditioned water F...

Page 47: ...s not match selected system type in Master Programming Push correct valve settings in Master Settings Motor Stall No Changes Detected in the Optical Sensor for 6 Seconds The motor is on but no encoder pulses are detected within a given duration while homing Check the P11 connection and trigger a manual regeneration Motor Run On No CAM Switch Change Detected The motor is on but no encoder pulses ar...

Page 48: ...verify that it functions correctly If the error re occurs unplug the unit and contact technical support 2 Regen Failure The system has not regenerated for more than 99 days or 7 days if the Control Type has been set to Day of Week Perform a Manual Regeneration to reset the error code If the system is metered verify that it is measuring flow by running service water and watching for the flow indica...

Page 49: ...49 Water Softener Flow Diagrams 2 Backwash Position 4 Slow Rinse Position 5 Rapid Rinse Position 1 Service Position 3 Brine Position 6 Brine Tank Fill Position ...

Page 50: ...50 1600 Brine System Standard Size Color 0 Red 1 White 2 Blue 3 Yellow 4 Green Injector Nozzle and Throat Chart for 1600 Brine Systems Flow Data and Injector Draw Rates Down Flow ...

Page 51: ..._________________________________________________________________________________________________________ ________________________________________________________________________________________________________________________________________ ________________________________________________________________________________________________________________________________________ ____________________...

Page 52: ...the warranty period the Company will at its option replace or recondition the product without charge Disclaimer of Warranty THE WARRANTY SET FORTH HEREIN IS GIVEN EXPRESSLY AND IS THE ONLY WARRANTY GIVEN BY THE COMPANY WITH RESPECT TO THE PRODUCT THE COMPANY MAKES NO OTHER WARRANTIES EXPRESS OR IMPLIED THE COMPANY HEREBY SPECIFICALLY DISCLAIMS ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT ...

Reviews: