TANDBERG 3000 MXP
306
Cable Specification
RS-530 Cable
TANDBERG MXP and Classic Endpoints that support External
Network
•
Connector on Tandberg End:
o
Female 26pin High Density DSUB Newark P/N 50F2055 or Equivalent
•
Connector on RS-530:
o
DSUB 25 pin Male
•
Cable
length:
o
1
meter
Signal Name
Female
26pin DSUB
(Tandberg end)
Pin Number
Male
25pin DSUB
RS-530 (DCE end)
Pin Number
Comments
Frame Ground
1
1
Do not connect shield to FGND
Signal Ground
19
7
Send Data (A)
Send Data (B)
11
12
2
14
Twisted Pair
Send Timing (A)
Send Timing (B)
17
18
15
12
Twisted Pair
Receive Data (A)
Receive Data (B)
13
14
3
16
Twisted Pair
Receive Timing(A)
Receive Timing (B)
15
16
17
9
Twisted Pair
Terminal Ready(A)
Terminal Ready(B)
20
21
20
23
Receiver Ready (A)
Receiver Ready (B)
22
23
8
10
Twisted Pair
LOS A
25
18
LOS A Unbalanced
Summary of Contents for 3000 MXP Profile
Page 14: ......
Page 141: ...Administrator Settings 127 PC Presentation shown in Wide stretched mode ...
Page 201: ...Administrator Settings 187 Voice Switched mode ...
Page 257: ...Peripheral Equipment 243 ...
Page 282: ...TANDBERG 3000 MXP 268 ...
Page 286: ...TANDBERG 3000 MXP 272 Top view ...
Page 302: ...TANDBERG 3000 MXP 288 Appendix 17 Dimensions Dimensions with Precision HD Camera ...
Page 303: ...Appendices 289 ...
Page 304: ...TANDBERG 3000 MXP 290 ...
Page 305: ...Appendices 291 ...
Page 307: ...Appendices 293 ...
Page 308: ...TANDBERG 3000 MXP 294 Top view with base Top view 32 monitor ...
Page 309: ...Appendices 295 Top view 42 monitor ...
Page 310: ...TANDBERG 3000 MXP 296 Codec ...
Page 312: ...TANDBERG 3000 MXP 298 Unscrew bolts as indicated and change codec ...