135
TROUBLESHOOTING
TROUBLESHOOTING
If the Battery Goes Dead
After the Fuel Runs Out
Bleeding the Air from the Fuel
System
1. Add fuel.
2. Loosen the vent plug (6) on the main fuel
filter (2).
3. Turn the starter key to the ON position and
wait for the air to bleed around the vent
plug (6).
4. When the air is bled and the fuel starts
coming from the vent plug (6), retighten
the vent plug (6).
5. Turn and hold the starter key to the ON
position for three minutes before turning it
back to the OFF position.
Supplement:
Air in the fuel system can
make it difficult to start the engine and cause
engine problems. Also bleed the air when
the fuel tank is emptied.
Disconnecting the jumper cables
Once the engine starts, disconnect the
jumper cables following the connection
procedure in reverse order.
1. Disconnect the clip of jumper cable (B)
from the problem vehicle’s engine block.
2. Disconnect the other clip of jumper cable
(B) from the rescue vehicle’s “–” terminal.
3. Disconnect the clip of jumper cable (R)
from the rescue vehicle’s “+” terminal.
4. Disconnect the other clip of jumper
cable (R) from the problem vehicle’s “+”
terminal.
Recharging
Have a Takeuchi sales or service outlet
recharge batteries that have gone dead.
E4J006
4
1
3
2
R
B
Rescue vehicle battery
Problem vehicle battery
From engine block
OFF
ON
START
L3D001
Summary of Contents for TCR50
Page 6: ...4 ...
Page 8: ...6 ...
Page 35: ...33 SAFETY Safety Signs Decals ...
Page 36: ...34 SAFETY Safety Signs Decals ...
Page 64: ...62 ...
Page 84: ...82 ...
Page 85: ...83 TRANSPORT Loading and Unloading 84 Hoisting the Machine 85 Securing the Machine 86 ...
Page 147: ...145 SPECIFICATIONS Main Specifications 146 Machine Dimensions 148 Operating Range 150 ...
Page 149: ...147 MEMO ...
Page 150: ...148 SPECIFICATIONS Machine Dimensions ...
Page 152: ...150 SPECIFICATIONS Operating Range ...
Page 154: ...152 ...
Page 155: ...153 OPTIONS General Precautions 154 Optional Equipment Mass 156 ...
Page 159: ...157 INDEX ...