141
TROUBLESHOOTING
“Open circuit” in items “19” and “20” means engine oil pressure reduction caused by an oil
shortage.
Error details
Error Code No.
16
17
18
19
20
21
22
When the key switch is turned ON, the engine oil pressure sensor
malfunctions.
When the key switch is turned ON, the charger outputs an ON (24V)
signal.
The status change (Low to High) of an open-circuit interlock signal is
recorded. Even if an open circuit is detected, the engine does not stop (if
the open-circuit interlock signal line is grounded). The “High” signal level
detected when the engine is started is recorded.
The status change (High to Low) of an open-circuit interlock signal is
recorded. When an open circuit is detected, the engine stops (if the open-
circuit interlock signal is in an OPEN state).
An error occurs on a comparative amplifier. A shoot-through current or
open circuit occurs.
A CAN communication error occurs. A communication error with ECM
occurs.
If a Warning Lamp Flashes
Summary of Contents for TCR50
Page 6: ...4 ...
Page 8: ...6 ...
Page 35: ...33 SAFETY Safety Signs Decals ...
Page 36: ...34 SAFETY Safety Signs Decals ...
Page 64: ...62 ...
Page 84: ...82 ...
Page 85: ...83 TRANSPORT Loading and Unloading 84 Hoisting the Machine 85 Securing the Machine 86 ...
Page 147: ...145 SPECIFICATIONS Main Specifications 146 Machine Dimensions 148 Operating Range 150 ...
Page 149: ...147 MEMO ...
Page 150: ...148 SPECIFICATIONS Machine Dimensions ...
Page 152: ...150 SPECIFICATIONS Operating Range ...
Page 154: ...152 ...
Page 155: ...153 OPTIONS General Precautions 154 Optional Equipment Mass 156 ...
Page 159: ...157 INDEX ...