Controlling with External Analog & Contact Signals                                 

------------------------------------------------------------------------------------ 
131 

Using External Control Terminals (ZX-S Series Type-LAN)   

 

This section covers proper methods when operating the ZX-S-LAN Series Power Supply externally. 
The External Control Terminal is located on the rear panel of the power supply.   

(A connector is provided for the terminal. Combined with FUNCTION items, this terminal can be applied 
in various means.) 

A specialized connector is attached to the ZX-S-LA Series. 

 

     
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Terminal 

No. 

Signal Name 

External ON/OFF Terminal 

 

External ON/OFF, Input Cut-0ff   

COM 

 

Monitor Terminal 

For Output Current 

Analog COM 

 

Output Voltage Control Terminal 

External Voltage Input Terminal 

(+) 

Output Voltage/Current Control 

Terminal 

External Resistance Terminal (A 

Curve) 

Output Voltage Control Terminal 

External Resistance Terminal (B, 

C Curve) 

Output Current Control Terminal 

External Resistance Terminal (A 

Curve) 

Output Current Control Terminal 

External Resistance Terminal   

(B, C Curve) 

10 

NC 

 

11 

Status Output 

LEVEL1_ALM 

12 

Status Output 

CV 

13 

Status Output 

P-ON 

14 

Input Cut-Off Terminal 

 

15 

Monitor Terminal   

For Output Voltage 

16 

Analog COM 

 

17 

Analog COM 

 

18 

Output Voltage Control Terminal 

External Resistance Terminal (A 

Curve) 

19 

Output Voltage Control Terminal 

External Resistance Terminal (B, 

C Curve) 

20 

Output Current Control Terminal 

External Voltage Input Terminal 

(+) 

21 

Output Current Control Terminal 

External Resistance Terminal (B, 

C Curve) 

22 

Series Operation Control Terminal 

 

23 

NC 

 

24 

Status Output 

Level2_ALM 

25 

Status Output 

CC 

26 

Status COM 

 

IN

OUT

1

13

26

14

外部コントロール用

コネクタ

直列コントロール用

コネクタ

外部コントロール用

コネクタ(付属)

1

13

26

14

ロックレバー

Series Control   

Connector 

External Control   

Connector 

External Control   

Connector (Accessory) 

Lock Lever 

Summary of Contents for ZX-S-1600LAN

Page 1: ...Constant Voltage Constant Current DC Power Supply series Instruction Manual...

Page 2: ...rm 35 Error Codes 37 Useful Function Memory 39 Saving in Memory 39 Loading from Memory 40 Panel Memory Savable Items List 41 Startup Mode Selection 42 Variable Slew Rate 43 Sequential ON OFF 45 Key Lo...

Page 3: ...attery 151 Loads with Reverse Current 152 Pulse Current Loads 153 Maintenance Warranty Period 155 Daily Maintenance Inspection 155 Cleaning Air Filter 156 Cleaning Panels 156 Inspecting Cables Termina...

Page 4: ...g from the outlet Continual use of the product if Continual use of the product if there are abnormal noises or smells Smoke appears Water or foreign objects enters the product may result in fire or el...

Page 5: ...r supply plug from the outlet power immediately and contact Takasago Exporting Please contact Takasago in advance if wishing to export or carry this product outside of Japan Using this product near re...

Page 6: ...e ZX S series with full digital control also grants settings with superior accurate reproduction Note Zoom method is the ability to output a high voltage in areas with low current and high current in...

Page 7: ...order outputs are toggled ON OFF through a multi connection cable Protection Functions Guards valuable loads and power supplies with Over Voltage Protection Over Current Protection Over Power Protecti...

Page 8: ...OCAL LOCAL Key Switches between LOCAL operated from the panel and REMOTE operated by control via serial data communication This is the front panel of the ZX S 800LN LOCK LOCK Key Locks panel from use...

Page 9: ...set the output voltage and output current Front panel diagram of ZX S 800LN Output Terminal for 800LN LAN 1600LN LAN DC Output Terminal The maximum current is 80A If more than 80A is outputted the OCP...

Page 10: ...erred to an external computer etc being accessed via serial interface FUNC Function Display Lamp Lights when Function settings are available PRESET Preset Display Lamp Lights when Preset settings are...

Page 11: ...h any other products SENSE Sensing Terminal Terminal for Remote Sensing MNT MNT Switch Swicth for the maintenance to rewrite F W Do not operate the switch during working If operate the product may not...

Page 12: ...tput ON OFF Control with External Contacts Slave Control Signal Input Connector for parallel operations Use for toggling the output ON OFF with external contacts M S CONTROL OUT Parallel Operation Con...

Page 13: ...About this Product 10 This is blank page...

Page 14: ...screws 2 items Output Terminal Screws M5 12mm bolts includes Flat washers and Spring washers 2 packages 400LN LAN 800LN LAN Attached to power supply M12 30mm bolts Flat washers Spring washers Nuts 2 p...

Page 15: ...If affixing to a rack attach ventilation panels to the rear of the rack to prevent Prohibited exhaust from the power supply from being released inside the rack Using this product near receivers radios...

Page 16: ...the device to prevent EMI Electromagnetic Interference Due to this even the slightest amount of leaked current may result in electric shock if not Mandatory properly grounded For safety reasons please...

Page 17: ...t the load terminal The noise level can be minimized smaller than the standard value by connecting the C1 and C2 close to the load terminal Using a small high frequency impedance for C1 and C2 cut the...

Page 18: ...e is being outputted from the power supply Prohibited Caution Use wires with sufficient cross section areas for load currents Mandatory Ex See Appendix Load Current vs Cross section areas Attach crimp...

Page 19: ...support rod to the remaining terminal cover inserting it into the center part of the cover and affix the rod in place by screwing an M3x6mm into it from the bottom of the cover Hook the terminal cover...

Page 20: ...ization are as followed Settings Item 400 N 400LAN 800 N 800LAN 1600 N 1600LAN Constant Voltage Set Value Constant Current Set Value Over Voltage Protection OVP Set Value Over Current Protection OCP S...

Page 21: ...ys once the Number Display lights up Backing Up Settings This power supply saves all settings in non volatile memory EEPROM just before the POWER switch is turned off or immdeitely before power is cut...

Page 22: ...ent display mode The voltage PRESET value will display in the top Number Display and the current limit PRESET value will display in the bottom Number Display Turn the VOLTAGE dial to adjust the Consta...

Page 23: ...with the set settings The OUTPUT and CV lamps will light CC CV OUTPUT POWER STEP CURRENT STEP VOLTAGE PRESET FUNC REMOTE LOCK 20 60 100 LMT 40 80 If the current limit value is set to a value lower tha...

Page 24: ...d the current PRESET value will display in the bottom Number Display Turn the CURRENT dial to adjust the Constant Current Set Value Turn the dial right to raise or left to lower the set value If the p...

Page 25: ...eturns to the measurement display Press the OUTPUT key Outputs with the set settings OUTPUT and CV lamp will light OUTPUT PRESET OVP OCP FUNC ALARM RESET While the PRESET lamp is lit all other keys no...

Page 26: ...UT Turn POWER switch OFF before wiring to the output terminal Danger While using remote sensing do not switch output lines using switches etc Doing so may lead to damaging the power supply Because the...

Page 27: ...he dial Press the key to finalize settings The top and bottom Number Displays will return to measurement display mode It is possible to continue to change other setting items without pressing the FUNC...

Page 28: ...CC Slew Rate Falling 400LN LAN 0 01A s 80 00A s 80 00A s 800LN LAN 0 1A s 160 0A s 160 0A s 1600LN LAN 0 1A s 320 0A s 320 0A s 7 Serial I F2 0 Serial Data Communication Control Remote Mode 0 Serial D...

Page 29: ...ffset Not displayed 25 Voltage Measurement Full Scale Not displayed 26 Current Measurement Offset Not displayed 27 Current Measurement Full Scale Not displayed 28 Calibration ZX S Type LAN External An...

Page 30: ...Action 1 Double Action 1 Double Action 60 Communication Functions Device Address 1 50 1 61 Bitrate 0 2400bps 1 9600bps 1 9600bps 2 19200bps 3 38400bps 62 Parity 0 No 0 No 1 ODD 2 EVEN 63 Command Form...

Page 31: ...on 100 Sequential Operation Function Sequential Operaton Mode 0 disable 1 enable Normal Mode 2 enable Continue Mode 0 disable 101 Sequential Operating Number of repetition 0 to 9999times 0 Continuous...

Page 32: ...ts of Parameter Default Value 112 Sequential Operation Function Sequential Operating OFF Time s 0 59 9s Setting Resolution 0 1s 0 0s 113 Sequential Operating OFF Time s 0 59 9s Setting Resolution 0 1s...

Page 33: ...ayed in the bottom Number Display Select Item No 51 with the dial Set Parameter to 0 or 1 with the dial Parameter Output is OFF COLD START after power is turned on Pressing the OUTPUT key will toggle...

Page 34: ...nnect the load from the power supply Turn the POWER switch ON with the Output Toggle mode set to 0 Set the output voltage settings lower than OVP level Turn OUTPUT to ON Gradually increase the Output...

Page 35: ...unction is set invalid and the voltage is immediately decreased MEMO During serial data communication recovery from alarm status is possible using commands During parallel operation where the Master u...

Page 36: ...section area wires that can flow rated current Turn the POWER switch ON with the Output Toggle mode set to Set the Output Current settings lower than OCP level Turn OUTPUT to ON Gradually increase the...

Page 37: ...ction is set invalid and the output current is immediately decreased MEMO During serial data communication recovery from alarm status is possible using commands During parallel operation where the Mas...

Page 38: ...he bottom Number Display Select Item No 14 with the VOLTAGE dial Set parameter to 0 or 1 with the CURRENT dial Parameter 0 When fan alarm is detected output continues Parameter When fan alarm is detec...

Page 39: ...d OCP keys simultaneously for more than 1 second to erase the displayed error code and FAn During serial date communication recovery from alarm status is possible using commands MEMO If a fan alarm oc...

Page 40: ...e main power Turn power switch OFF Check device s power supply BST_NRDY E008 Slave unit s input voltage is abnormal or POWER switch is OFF Check whether slave unit s power switch is ON Device Detectio...

Page 41: ...to initialize during startup Cancel by pressing OVP OCP keys simultaneously or by the remote control command ALARM CLEAR E2P Failure for LAN E120 Failure to initialize during startup Restart power su...

Page 42: ...ion by holding down Memory A B C key for more than 1 second Saves current set values The light will blink faster until finished Once saving is complete the display will return to measurement display m...

Page 43: ...wish to load from The voltage and current values stored in memory will blink in the Number Display Press the same memory key to cancel Pressing a different memory key at this point will display the v...

Page 44: ...avable Parameters PRESET CV Set Value CC Set Value OVP Set Value OCP Set Value FUNC 2 Selection of Startup Mode 3 CV Slew Rate Rising 4 CV Slew Rate Falling 5 CC Slew Rate Rising 6 CC Slew Rate Fallin...

Page 45: ...urrent pulse to nonlinear loads such as diodes etc Setting Procedures Press the Function FUNC key FUNC lamp will light Settings Item Number will display on the top Number Display and parameters on the...

Page 46: ...e VOLTAGE dial Assign the Startup Priority Mode by setting the parameter to 2 or 3 with the CURRENT dial Set Value 2 CV Priortiy Variable Slew Rate Set Value 3 CC Priority Varialbe Slew Rate The range...

Page 47: ...Set Value 5 Rising Current Slew Rate Set Value 6 Falling Current Slew Rate Assign the set value using the CURRENT dial Range 400LN LAN 0 01A s 80 00 s 800LN LAN 0 1A s 160 0 s 1600LN LAN 0 1A s 320 0...

Page 48: ...1 and last sequential slave n TERMINATION switch to ON Set all other sequential slaves to OFF Caution T485 M Or KXC 300 Sequential Master SERIAL I F 1 SERIAL I F 2 TERMINATIO N LINE INPUT OF F O N I N...

Page 49: ...OFF Delay Time settings have a range of 0 00 99 99 Factory default is 0 00s no delay time Setting ON Delay Time Select Item Number 8 with the VOLTAGE dial Set ON Delay Time with the CURRENT dial Sett...

Page 50: ...Master and Slave settings with the CURRENT dial Master Unit is Address Set the Slave Unit Address to any value except 1 Press the FUNC key to finish Number Display will return to mesurement display m...

Page 51: ...Settings Pressing the LOCK key will restrict key inputs LOCK lamp will light The status of the Lock Key can be selected under the FUNCTION Settings Item Number 53 parameters from the following 3 types...

Page 52: ...on the top Number Display and parameters on the bottom Number Display Select Item Number 72 with the VOLTAGE dial Set the Internal Resistance value with the CURRENT dial Range is 0 00 2 00 400LN LAN...

Page 53: ...s known as the Moving Average Method Setting Procedures Press the Function FUNC key FUNC lamp will light Settings Item Number will display on the top Number Display and parameters on the bottom Number...

Page 54: ...display on the top Number Display and parameters on the bottom Number Display Select Item Number 13 with the dial Set Compensation Mode with dial 0 Compensation Function is turned OFF 1 Once compensat...

Page 55: ...value is positive enlarged In the event of the previous corrected value is negative enlarged Latest output after setting the Linearity Compensation to OFF Previous correction value Output corrected by...

Page 56: ...m 0 0 59 9sec Note The accuracy of the sequential operating time is Approx 0 5 and settable Min resolution is 0 1 sec However it may happened to have any influence against rising and falling time of o...

Page 57: ...For the items and parameters please refer to List of Setting Items ZX S series will be ready for sequence operation after setting 1 or 2 for item 100 and pressing FUNC button 0 Sequential Operation d...

Page 58: ...ll be stopped during the sequential operation due to the error and turning off of the ZX S series V A t tC tC tB1 tA tA Operating Time with Memory A tB Operating Time with Memory B tB1 Operated time w...

Page 59: ...ction Memory A Memory B Memory C Keep the output of memory C Press Function Key FUNC Set the required parameters for item 114 For the items and parameters please refer to List of Setting Items additio...

Page 60: ...CTION Setting Item 104 23 4 sec 2 The sequential operation will not be executed with the setting of 0 hrs 0 min and 0 0 sec e g 1 There is no OUTPUT with the Memory B if the operation time for the Mem...

Page 61: ...ion Memory A Memory B Memory C tA Operating Time with Memory A tB Operating Time with Memory B tC Operating Time with Memory C tOFF Operating Time with OUTPUT OFF 4 It is enable to use slew rate durin...

Page 62: ...on in case of non achieving the target value by slew rate V A t tOff tC tB tA Memory A Memory B Memory C tA Operating Time with Memory A tB Operating Time with Memory B tC Operating Time with Memory C...

Page 63: ...Useful Function 60 This is blank page...

Page 64: ...RJ 45 of remote control connector LAN Main unit side RJ 45 connector 3 5 7 Pin No 1 RXD NC NC Name TXD IN IN OUT OUT 4 6 8 Pin No 2 NC RXD NC Name TXD IN IN OUT OUT Pin assignment of remote control co...

Page 65: ...ne Connection cutting off Connection establishing PC ZX LNseries ZX HNseries LAN I F SYN ACK The data is discarded even if receives the data from serial I F in connection cutting off status SYN ACK Th...

Page 66: ...lishing PC ZX LNseries ZX HNseries LAN I F Tranmits Keep Alive packet as detects LAN I F detects non communication for ten seconds KeepAlive KeepAlive ACK KeepAlive Failure occurrence of physical conn...

Page 67: ...TAKASAGO s power supply ZX Series ZX Series ZX LN Series ZX HN Series ZX Series ZX LN Series ZX HN Series LAN TCP IP PC Communication Data Analysis Communication Data Analysis Communication Data Anal...

Page 68: ...01 2012 00 00 00 Copyright c TAKASAGO LTD 2012 All Rights Reserved Display Ex The connection which has been already connected as the usual operation is cut Restart the product in case that reflects th...

Page 69: ...ave by S command after settings change MAC Address cannnot be changed If wants to reflect the settings please save the current settings by s command and then restart the product Caution Configuration...

Page 70: ...y Set default gateway of LAN I F Initial setting value 0 0 0 0 7 port no Set passive open port of LAN I F Initial setting value 50001 Setting range 1 to 65535 S save E2PROM Save current setting inform...

Page 71: ...UT IN OUT 4 6 8 Pin No 2 TX RX GND Name NC IN OUT IN OUT Remote Control at Master unit setting Remote control at Slave unit setting Sequential Control at Master unit setting 3 5 7 Pin No 1 TX RX NC Na...

Page 72: ...485 Multiple Connections The diagram below shows the connections for controlling multiple ZX S Series power supplies with one computer By setting each individual address for the ZX Series power suppli...

Page 73: ...serial port settings Communication cannot be established if settings differ Set the bitrate and parity under FUNCTION Setting Item 61 Bitrate and Item 62 Parity See page 24 Setting changes will take...

Page 74: ...rol to the front panel from Remote Control Status press the LOCAL key on the front panel The REMOTE LED will turn off and Local control with the front panel will be granted OUT PUT PRESE T OVP OCP POW...

Page 75: ...OTE LED turns on PC LAN RS 485 Device Address Connection Configuration OUT PUT PRESE T OVP OCP POWER FUNC LOCAL LOCK DISPLAY A B C MEMORY CC CV O UTPUT PO WER ST EP PRESET FUNC REMO TE LOCK AL ARM RES...

Page 76: ...mands and respones are ASCII character strings One character space is required between command words and parameters Ex ADDRess Within text command word stands for command characters such as ADDRess OU...

Page 77: ...Form OUTPu Recognized as illegal command Inputting SCPI Commands SCPI commands use the following hierarchical structure Ex ALM Root Command CLEar Command CONTain Pass Command CC NRf Command Parameter...

Page 78: ...pointers also will not be affected by Common Commands Ex ALM CLEAR IDN CONTAIN CC Delimiter Please attach any of the following to the end of the program message CR LF CR LF CR Carriage Return 0x0d LF...

Page 79: ...mmand Type IDN Requests device information QUERY Only RST Resets set parameters SET Only Identification Query Function Retrieves device information Name of Manufacturer Name of Model Software Version...

Page 80: ...vice Address Function Assigns the device address for ZX power supplies Format ADDRess NR Type SET command only Range Address 0 is a global address Assign addresses to all multi connected ZX S Series D...

Page 81: ...cels generated Over Voltage Over Current alarm Format ALM CLEar Type SET command only No parameters Ex ALM CLE LM CONTain CC Sets whether to contain CC_STS in LEVEL1_ALM Function Sets whether to conta...

Page 82: ...ttached While operating as parallel operation slave unit Sequence operation in progress Ex ALM CONT CV 0 ALM CONT CV 0 LM CONTain PL Sets whether to contain PL_STS in LEVEL1_ALM Function Sets whether...

Page 83: ...PONB NRf Type SET command QUERY command Parameters 0 Does not include in LEVEL1_ALM 1 Includes in LEVEL1_ALM Response Same as parameters Restrictions Alarm response is returned for normal SET command...

Page 84: ...en POWER is ON Both MODE Sets Startup Mode Both STATe Sets Output ON OFF Both OUTPut DELay ON Sets Output ON Delay Time Function Sets Output ON Delay Time Same as FUNCTION Settings Item 8 Format OUTPu...

Page 85: ...gress Ex OUTP DEL OFF 56 78 OUTP DEL OFF 56 78 OUTPut EXTernal MODE Sets operation mode for Output Contorl at External Contact Points Function Sets operation mode for Output Control at External Contac...

Page 86: ...lowing conditions While operating as a series operation slave unit While operating as a parallel operation slave unit Sequence operation in progress Ex OUTP HOT 1 OUTP HOT 1 OUTPut MODE Sets Startup M...

Page 87: ...STATe String Type SET command QUERY command Paramters ON Output ON OFF Output OFF Response Same as parameter Restrictions Alarm response is returned for normal SET commands in the following condition...

Page 88: ...ry Command Type MEASure CORRection MODE Sets operation mode for the Linear Compensation Function Both MVAV Sets Moving Average process for measurement values Both SCALar CURRent DC Retrieves current m...

Page 89: ...conditions While operating as a parallel operation slave unit Sequence operation in progress Ex MEAS CORR MODE 0 MEAS CORR MODE 0 MEASure MVAV Sets Moving Average process for Measurement Values Funct...

Page 90: ...er measurement values Format MEASure SCALar POWer DC Type QUERY command only Response Returns same resolution data as the Power Meter Restrictions Alarm response is returned for normal SET commands in...

Page 91: ...l Sets OCP Current Both SLEW RISing Sets CC Slew Rate Rising Both FALLing Sets CC Slew Rate Falling Both MEMory RECall Loads from Panel Memory SET only MODE Sets Loading Order for Panel Memory Both ST...

Page 92: ...ers Range varies on the model and the number of parallel connected devices Response Same as parameters Output Current A Ranges Model Type No of Parallel Connected Devices N LA Idependent Operation Res...

Page 93: ...s on the model and the number of parallel connected devices Response Same as parameters OCP Current A Ranges Model Type No of Parallel Connected Devices LA Idependent Operation Restrictions Alarm resp...

Page 94: ...the model and the number of parallel connected devices Response Same as parameters CC Slew Rate Unit A Ranges Model Type No of Parallel Connected Devices LA Idependent Operation Restrictions Alarm re...

Page 95: ...ies operation slave unit While operating as a parallel operation slave unit Ex ZX S 400LN Idependent Operation CURR SLEW FALL 80 CURR SLEW FALL 80 00 SOURce MEMory RECall Loads from Panel Memory Funct...

Page 96: ...as a series operation slave unit While operating as a parallel operation slave unit Sequence operation in progress Ex MEM REC MODE 1 MEM REC MODE 1 SOURce MEMory STORe Saves to Panel Memory Function S...

Page 97: ...l connected devices Response Same as parameters Internal Resistance Ranges Model Type No of Parallel Connected Devices LA Idependent Operation Restrictions Alarm response is returned for normal SET co...

Page 98: ...hile operating as a series operation slave unit While operating as a parallel operation slave unit Sequence operation in progress Ex VOLT 80 VOLT 80 00 SOURce VOLTage PROTection LEVel Sets OVP Voltage...

Page 99: ...operating as a parallel operation slave unit Sequence operation in progress Ex VOLT SLEW RIS 160 VOLT SLEW RIS 160 0 SOURce VOLTage SLEW FALLing Sets CV Slew Rate Falling Function Sets the CV slew ra...

Page 100: ...tus TRIP ON Normal EXT_TRIP_STS External TRIP Status TRIP ON Normal _ OVP Adjustment Status 1 Above OVP level Below OVP level _ OCP Adjustment Status 1 Above OCP level Below OCP level _ CP Operation S...

Page 101: ...that is running as a slave unit under parallel operation Ex STAT MEAS COND 000184 P ON_B P ON_M PL_STS represents state of 1 STATus MEASure PARallel Retrives No of Parallel Connected Devices Function...

Page 102: ...Both CONTrol CURRent MODE Sets mode for Current Settings Control Method Both VOLTage MODE Sets mode for Voltage Settings Control Method Both ERRor Reads Error Message QUERY only KEYLock MODE Sets LOCK...

Page 103: ...l operation slave unit Sequence operation in progress Ex SYST COMM SER BAUD 3 SYST COMM SER BAUD 38400 SYSTem COMMunicate SERial RECeive PACE Sets Acknowledge Response Function sets the Acknowledge Re...

Page 104: ...her to add on units to the Query Response Format SYSTem COMMunicate SERial UNIT Nrf Type SET command QUERY command Parameters 0 Do not add units Default Settings 1 Add on units Response Same as parame...

Page 105: ...perating as a parallel operation slave unit Sequence operation in progress Ex SYST CONT CURR MODE 1 SYST CONT CURR MODE 1 SYSTem CONTrol VOLTage MODE Sets Mode for Voltage Setting Control Method Funct...

Page 106: ...d instead of numeral in parameter etc 109 Missing parameter Too few parameters 120 Numeric data error Numerical data error Exceeds range etc 140 Character data error Character data error 150 String da...

Page 107: ...as a series operation slave unit While operating as a parallel operation slave unit Sequence operation in progress Ex SYST KEYL MODE 1 SYST KEYL MODE 1 SYSTem MONitor MODE Sets Voltmeter Ammeter Disp...

Page 108: ...x SYST PRES MODE 0 SYST PRES MODE 0 SYSTem SERies Sets Master and Slave for Series Operation Function Sets the Master and Slave for Series Operation Same settings as FUNCTION Settings Item 73 Format S...

Page 109: ...e is returned for normal SET commands in the following conditions While operating as a series operation slave unit While operating as a parallel operation slave unit Sequence operation in progress Ex...

Page 110: ...is detected severe breakdown OVP OCP triggered Restrictions Alarm response is returned for normal SET commands in the following conditions All ZX S Series power supplies excluding 1600W models SET com...

Page 111: ...uence Operating Execution Frequency Finished OUTPUT OFF Both STATus Retrieving Sequence Operating Status QUERY only SEQuence MODE Sets Sequence Operating mode Function Sets the sequence operating mode...

Page 112: ...e unit While operating as a parallel operation slave unit Sequence operation in progress Ex SEQ COUNt 1 SEQ COUNt 1 SEQuence MEMA Sets Memory A Operating Time Function Sets the memory A operating time...

Page 113: ...operating as a parallel operation slave unit Sequence operation in progress Ex SEQ MEMB 100 10 10 0 SEQ MEMB 100 10 10 0 SEQuence MEMC Sets Memory C Operating Time Function Sets the memory C operating...

Page 114: ...el operation slave unit Sequence operation in progress Ex SEQ OFF 100 10 10 0 SEQ OFF 100 10 10 0 SEQuence OUTPut Sequence Operating Execution Frequency Finished OUTPUT OFF Function Sets the sequence...

Page 115: ...the retrieving sequence operating status Format SEQuence STATus Type QUERY only Response 1 2 3 1 Sepuence main state Stopped In action 2 Sepuence sub state Waiting Memory A operation Memory A operati...

Page 116: ...nd Name Control Command Functions Page No Assigns device address Page 115 Executes alarm reset Page 115 Resets set parameters Page 115 Sets OCP current Page 116 Sets OVP voltage Page 116 M Sets output...

Page 117: ...fined command is received When command parameters exceed the range When a character or symbol other than numerals 0 9 and decimal point is sent in parameters When sent with a single parameter containi...

Page 118: ...ss 1 to ZX power supply Ex A1 OT1 A2 OT1 Errors due multple address assignment commands Executes Alarm Reset Function Executes alarm reset cancels triggered OVP OCP alarms Format Set value Set value R...

Page 119: ...es result in parameter errors Range varies on the model and number of parallel connected devices OCP Current Range Model Type No of Parallel Connected Devices Idependent Operation Ex A1 LC44 0 Sets OV...

Page 120: ...ange Values other than ranges result in parameter errors Range varies on the model and number of parallel connected devices Output Current Range Model Type No of Parallel Connected Devices Idependent...

Page 121: ...nput power relay trip When TRIP is detected severe breakdown OVP OCP triggered Values other than 0 1 or 2 result in parameter errors Ex A1 TP1 Serious failure is defined as when an alarm can be cancel...

Page 122: ...See page 117 Output Current Ranges for Max no of decimal places OVP Voltage Set Values Max no of decimal places is 2 OCP Current Set Value See page 116 OCP Current Ranges for Max no of decimal places...

Page 123: ...atus is represents as 0 or 1 Retrived Status Information List Bit Status Name Summary _ P ON Master Status Main Power Supply ON Main Power Supply OFF _ALM OHP Over Heating Protection Error Error Norma...

Page 124: ...cified ZX power supply s Output Voltage Measurement Value Max no of decimal places is 2 Ex A1 TK4 10 00V Read Back Measured Current Data Function Retrives the measured current data from the ZX power s...

Page 125: ...control functions using multi connecting cables are only usable between ZX S Series power supplies of the same model If wishing to connect other Takasago products which are capable of multi connectio...

Page 126: ...ERMINATION OFF ON IN OUT M S CONTROL SENSE DC OUTPUT 100 240 50 60H 7A MAX LINE INPUT SERIAL I F 1 SERIAL I F 2 TERMINATION OFF ON IN OUT M S CONTROL SENSE DC OUTPUT 100 240 50 60H 7A MAX LINE INPUT M...

Page 127: ...e bottom Number Display Total current value is displayed in the bottom Number Display Select power display with the Display key to display total power values Error Codes Error Codes Display List for M...

Page 128: ...Load s plus terminal Connect wires from the Master s minus terminal to the Load s minus terminal Control Terminal Wiring Connect wires from the Slave s external control connector No 22 terminal to the...

Page 129: ...Change the set value to 1 Slave Mode with CURRENT dial Press the FUNC key again to finalize settings Turn the POWER switch OFF Device will operate as Slave unit when the POWER switch is turned ON aga...

Page 130: ...g as Constant Voltage Power Supply under Basic Operations on how to do this Press the FUNC key and turn the VOLTAGE dial to display Settings Item 37 in the top Number Display Adjust the Slave unit s s...

Page 131: ...p Number Display 10 Adjust the Slave unit s settings with the Current dial to match the measured Master Unit s output voltage displayed on the digital multimeter 11 Press the FUNC key of the Salve uni...

Page 132: ...connect it to M S CONTROL IN as shown in the diagram below Cable connector XG5M 1432 N or XG5M 1435 N OMRON Connector Semi Cover XG5S 0701 OMRON Contact XG5W 0031 N for XG5M 1432 N OMRON XG5W 0034 N f...

Page 133: ...rameter 2 Allows the output to be toggled from the panel when the external contacts are closed Also sets the Output OFF if the external contact is opened Output can be controlled by panel or remote co...

Page 134: ...rminal A Curve 7 Output Voltage Control Terminal External Resistance Terminal B C Curve 8 Output Current Control Terminal External Resistance Terminal A Curve 9 Output Current Control Terminal Externa...

Page 135: ...or Output status Master Slave Series Operation How to Insert Wire into Connector Push a flat head screwdriver into the square hole Insert the stripped wire as shown in the right diagram in the hole wh...

Page 136: ...t External Contact Points to be used Factory default settings are set to Invailid Connecting Wire the cables to the external control connector accessory terminal s No 1 and 2 The external control conn...

Page 137: ...s No 14 and 2 The external control connectors can be simply removed by lowering the lock levers on both sides 14 IN OUT 14 2 Shutdowning with short circuit make of contact b is standard Shutdowning w...

Page 138: ...Output Voltage V Max Output Voltage V The output accuracy for the external resistance is the set voltage 0 2 of Rated Output Voltage when 10 Connecting Connect the resistor to accessory connector ter...

Page 139: ...istance External Resistance External Resistance Press the FUNC key again to finish Returns Number Display back to measurement display mode Canceling Output Voltage Control via External Voltage Resista...

Page 140: ...istance is the set voltage 0 1 of Rated Output Voltage Connecting Connect the resistor to accessory connector terminals No 7 and 19 IN OUT 19 7 Setting Procedures Set to parameter 3 External Resistanc...

Page 141: ...he set voltage 0 1 of Rated Output Voltage Connecting Connect the resistor to accessory connector terminals No 7 and 19 IN OUT 19 7 Setting Procedures Set to parameter 4 External Resistance Type C acc...

Page 142: ...llowing formula Output Voltage V Max Output Voltage V The output accuracy for the external voltage is the set voltage 0 1 of Rated Output Voltage Connecting Connect the voltage source to accessory con...

Page 143: ...la Output Current A Max Output Current A The output accuracy for the external resistance is the set current 1 of Rated Output Current when 10 Connecting Connect the resistor to accessory connector ter...

Page 144: ...Resistance 10k External Resistance 10k Press the FUNC key again to finish Returns the Number Display back to measurement display mode Canceling Output Voltage Current via External Voltage Resistance T...

Page 145: ...stance is the set current 0 5 of Rated Output Current Connecting Connect the resistor to accessory connector terminals No 9 and 21 IN OUT 21 9 Setting Procedures Set to parameter 3 External Resistance...

Page 146: ...the set current 0 5 of Rated Output Current Connecting Connect the resistor to accessory connector terminals No 9 and 21 IN OUT 21 9 Setting Procedures Set to parameter 4 External Resistance Type C a...

Page 147: ...s what can produce a 1mA current The output current is derived from the following formula Output Current V Max Output Current V The output accuracy for the external resistance is the set current 0 5 o...

Page 148: ...utput Voltage Monitor The accuracy for the output voltage monitor is 0 2 2mV Connecting Connect the meter or recorder to accessory connector terminals No 4 and 15 Output Current Monitor The accuracy f...

Page 149: ...ollowing for details on each terminal s signals Terminal Signal Name Contents LEVEL1_ALM Light failure OVP OCP has occurred LEVEL2_ALM Alarm has occurred Indude Several Alarms CV_STS Running in Consta...

Page 150: ...p will light Settings Item Number top and parameters bottom will appear in the Number Display Select the Item number with the VOLTAGE dial Item 74 CV_STS Item 75 CC_STS Item 76 PL_STS Change the param...

Page 151: ...Controlling with External Analog Contact Signals 148 This is blank page...

Page 152: ...l when charge current is above 2A it is necessary to cool D1 by attaching an appropriate radiator to it Connection for Battery Charging Set the OUTPUT key settings to TOGGLE when the input power switc...

Page 153: ...stant Current Power Supply on how page 18 Set the charge terminal voltage with the VOLTAGE dial Set only the forward voltage to D1 high 0 6V 0 8V When finished press the FUNC key again to finalize set...

Page 154: ...charge current with the CURRENT dial See Operating as a Constant Current Power Supply on how Set the maximum voltage with the VOLTAGE dial Deriving the maximum output voltage open circuit voltage of b...

Page 155: ...put voltage Please use specialized break units etc to suppress the generation of over voltage when there is regenerative reverse current in the motor inverter load Reverse Current IR Power Supply VO D...

Page 156: ...current is in a pulsing state This cannot be determined by this device s ammeter alone due that it only displays the average output current value If the constant current circuit power limit circuit is...

Page 157: ...Special Loads 154 This is blank page...

Page 158: ...other entity other than Takasago shall impose a fee Requests When making repair requests please include the device s product number 12 digit number at base of product and firmware version number See p...

Page 159: ...ir gun or vacuum cleaner If accumulation is severe wipe the area with a synthetic detergent diluted in water and allow it to dry before attaching the panel To remove the panel Example with ZX S 400LN...

Page 160: ...acing Fan Motor Remove the four M3 screws attached to the fan motor Pull out the fan motor Disconnect the power wire connector black attached to the circuit board Connect the new fan motor s connector...

Page 161: ...is a general lifespan of parts It is recommend changing parts after 5 and 10 years to ensure prolong use Please be careful not to place this product in high temperature and humidity environments areas...

Page 162: ...RRENT dial See Operating as Constant Voltage Power Supply under Basic Operations on how Press the PRESET key again and then press the OUTPUT key to set output to ON Adjust so that the digital multimet...

Page 163: ...ltage Settings Please return the voltage current set values back to normal before use FUNC lamp will light and the display on the bottom Number Display will light out MEMO OUTPUT PRESET OVP OCP FUNC A...

Page 164: ...used for current measurement displays to 0 010mV For 400LN LAN use 10mA with the CURRENT dial For 800LN LAN use 0 005mV equivalent to 10m For 1600LN LAN use 0 025mV equivalent to 100m Set FUNCTION Se...

Page 165: ...the FUNC key to complete full scale calibration of the output current settings This completes offset full scale calibration of Output Current Settings Please return the voltage current set values back...

Page 166: ...e settings Press the OVP key Set to 88 00V with the VOLTAGE dial Input an external voltage of 0 00 Press the OUTPUT key to set output to ON Calibration Circuit Digital Multimeter CC CV OUTPUT POWER ST...

Page 167: ...urement displays to 80 00V with the CURRENT dial 4 Press the FUNC key to complete full scale calibration of output voltage control with external voltage 5 This completes offset full scale calibration...

Page 168: ...l resistance to infinity open Press OUTPUT key to set the output to ON Calibration Circuit Digital Multimeter CC CV OUTPUT POWER STEP CURRENT STEP VOLTAGE PRESET FUNC REMOTE LOCK 20 60 100 LMT 40 80 C...

Page 169: ...rement displays to 80 00V with the CURRENT dial Press the FUNC key to complete full scale calibration of output voltage control with external resistance A This completes offset full scale calibration...

Page 170: ...short Press the PRESET key and then the OUTPUT key to set the output to ON Calibration Circuit Digital Multimeter CC CV OUTPUT POWER STEP CURRENT STEP VOLTAGE PRESET FUNC REMOTE LOCK 20 60 100 LMT 40...

Page 171: ...ment displays to 80 00V with the CURRENT dial Press the FUNC key to complete full scale calibration of output voltage control with external resistance B This completes offset full scale calibration of...

Page 172: ...sistance to 10k IN OUT 19 7 Press the OUTPUT key to set the output to ON Calibration Circuit Digital Multimeter CC CV OUTPUT POWER STEP CURRENT STEP VOLTAGE PRESET FUNC REMOTE LOCK 20 60 100 LMT 40 80...

Page 173: ...ltage measurement displays to 80 00V with the CURRENT dial Press the FUNC key to complete full scale calibration of output voltage control with external resistance C This completes offset full scale c...

Page 174: ...o 88 00 For 1600LN LAN set to 176 0A Input an external voltage of 0 10 IN OUT 4 20 Press the OUTPUT key to set the output to ON CC CV OUTPUT POWER STEP CURRENT STEP VOLTAGE PRESET FUNC REMOTE LOCK 20...

Page 175: ...current measurement displays the set value with the CURRENT dial For deriving the set value see Output Current Control with External Voltage Press the FUNC key to complete full scale calibration of o...

Page 176: ...external resistance to IN OUT 8 6 Press t the OUTPUT key to set the output to ON CC CV OUTPUT POWER STEP CURRENT STEP VOLTAGE PRESET FUNC REMOTE LOCK 20 60 100 LMT 40 80 CC CV OUTPUT POWER STEP CURRE...

Page 177: ...current measurement displays the set value with the CURRENT dial For deriving the set value see Output Current Control with External Resistance Press the FUNC key to complete full scale calibration o...

Page 178: ...Set external resistance to IN OUT 21 9 Press the OUTPUT key to set the output to ON CC CV OUTPUT POWER STEP CURRENT STEP VOLTAGE PRESET FUNC REMOTE LOCK 20 60 100 LMT 40 80 CC CV OUTPUT POWER STEP CU...

Page 179: ...nt measurement displays the set value with the CURRENT dial For deriving the set value see Output Current Control with External Resistance Press the FUNC key to complete full scale calibration of outp...

Page 180: ...external resistance to IN OUT 21 9 Press the OUTPUT key to set the output to ON Calibration Circuit CC CV OUTPUT POWER STEP CURRENT STEP VOLTAGE PRESET FUNC REMOTE LOCK 20 60 100 LMT 40 80 CC CV OUTPU...

Page 181: ...ent measurement displays the set value with the CURRENT dial For deriving the set value see Output Current Control via External Resistance Press the FUNC key to complete full scale calibration of outp...

Page 182: ...the top Number Display to Settings Item 24 with the VOLTAGE dial to display the voltage measurement value at the bottom Adjust the measurement value displayed in the bottom Number Display to the same...

Page 183: ...oltage measurement with the CURRENT dial Press the FUNC key to complete voltmeter full scale calibration This completes voltmeter calibration Please return the CV set values back to normal before use...

Page 184: ...put current measurement with the CURRENT dial Press the FUNC key to complete full scale calibration of the ammeter Set FUNCTION Settings Item 1 Sink Function to 1 1 ON and Settings Item 13 Linearity c...

Page 185: ...s displayed in the digital multimeter mV used for output current measurement with the CURRENT dial Press the FUNC key to complete ammeter full scale calibration This completes ammeter calibration Plea...

Page 186: ...t to 0 00V with the VOLTAGE dial and 40 00A with the CURRENT dial For 400LN LAN set to 40 00A For 800LN LAN set to 80 00 For 1600LN LAN set to 160 0A Press the PRESET key and then the OUTPUT key to se...

Page 187: ...easurement displays Output Voltage Digital Multimeter No 1 8 with the CURRENT dial Press the FUNC key to complete full scale calibration of output voltage monitor This completes offset full scale cali...

Page 188: ...ESET key and set to 1 00V with the VOLTAGE dial and 40 00A 160 0A with the CURRENT dial For 400LN LAN set to 40 00A For 800LN LAN set to 80 00 For 1600LN LAN set to 160 0A Press the PRESET key Set the...

Page 189: ...ement displays Output Current 4 16 with the CURRENT dial For 400LN LAN derives from Output Current 4 For 800LN LAN derives from Output Current 8 For 1600LN LAN derives from Output Current 16 Press the...

Page 190: ...00LAN 1600LN 1600LAN Power Source AC85 250 Single Phase 45Hz 65 Input Current 1 100 Input 6 12 5A 24A 200 Input 3 6A 12A Input Power Factor 2 Above 0 99 Power Efficiency 3 0 75 Rush Current Peak Value...

Page 191: ...value Resolution 10mA 10mA 100mA Load Regulation 10 Below 0 03 3mA of rated output current Line Regulation 5 Below 0 03 2 A of rated output current Ripple Effective Value 6 20 A 40mA 80mA Temperature...

Page 192: ...Measure Accuracy 13 21 0 5 of reading 4 40mA 0 5 of reading 8 80mA 0 5 of reading 2 200mA Temperature Coefficient Typical Value 21 100 Power Meter 4 Digit Digital Meter Maximum Display 21 999 9W 999...

Page 193: ...nterface IEEE802 3 10BASE T RJ 45 connector Protocol TCP IP Display LINK ACT Communication speed 10Mbps duplex Half duplex AutoMD MDI X Incimpatible SERIAL IF Interface RS 485 Synchro Start Stop synch...

Page 194: ...vers once values return within ratings Over Heating Protection Circuit Stops switching shuts off output and displays alarms if the temperature of the radiating section heat exceeds 85 1600L LA 95 due...

Page 195: ...er unit Master Slave Series Operation 15 Output ON OFF Toggle Control Can be controlled at external contact or photocoupler Monitor Output Output 16 Current 17 15 Able to control a maximum of 2 series...

Page 196: ...input and chassis output and chassis Withstanding Voltage 1 5 1 minute Between each input and output input and chassis Relative Ground Voltage At peak voltage value within 500 between Output and Groun...

Page 197: ...5 D 429 5 W 130 H 405 D Max Dimensions 19 107 W 147 H 505 D 214 5 W 147 H 513 D 436 W 139 H 543 D Weight 5 1kg 5 2kg 7 9kg 8 0kg 15 0kg 15 1kg Output Terminal Bar Terminal 5 Screws Bar Terminal 12 Bol...

Page 198: ...er 1 Item M3 6 screws 2 Items Output Terminal Screws M5 12mm bolts includes flat washers spring wasters 2 Packages Attached to power supply Front Terminal Cover 1 Package Dummy Connector Attached to p...

Page 199: ...Specifications 196 This is blank page...

Page 200: ...197 External Diagrams ZX S 400LN 400LAN 4 M3...

Page 201: ...Appendix 198 ZX S 800LN 800LAN...

Page 202: ...Appendix 199 ZX S 1600LN 1600LAN...

Page 203: ...q 325sq 400sq 500sq 1 25sq AWG6 0 AWG5 0 AWG4 0 AWG3 0 AWG2 0 AWG1 0 AWG1 AWG2 AWG3 AWG4 AWG5 AWG6 AWG7 AWG8 AWG9 AWG10 AWG11 AWG12 AWG13 AWG14 AWG15 AWG16 AWG17 1A 10A 100A 1000A 1 10 100 1000 mm2 Ap...

Page 204: ...Copyright 2018 Takasago LTD Address 1 24 16 Mizonokuchi Takatsu ku Kawasaki shi Kanagawa 213 8558 Japan ZX S LN LANseries Instruction Manual 2019 2 Rev1 0 DOC 1870 01...

Reviews: