Using via Digital Data Communication
------------------------------------------------------------------------------------
89
[SOURce]:CURRent[:LEVel][:IMMediate][:AMPLitude]
:Setes Output Current
Function:Sets the output current
Format:[SOURce]:CURRent[:LEVel][:IMMediate][:AMPLitude] <NRf>
Type:SET command, QUERY command
Parameters:Range varies on the model and the number of parallel connected devices
Response:Same as parameters
Output Current(A) Ranges
Model(Type)
No. of
Parallel
Connected Devices
400LN/LAN
800LN/LAN
1600LN/LAN
1(Idependent Operation)
0.00~42.00
0.00~84.00
0.0~168.0
2
0.00~84.00
0.0~168.0
0.0~336.0
3
0.0~126.0
0.0~252.0
0.0~504.0
4
0.0~168.0
0.0~336.0
0.0~672.0
5
0.0~210.0
0.0~420.0
0.0~840.0
6
0.0~252.0
0.0~504.0
0~1008
7
0.0~294.0
0.0~588.0
0~1176
8
0.0~336.0
0.0~672.0
0~1344
9
0.0~378.0
0.0~756.0
0~1512
10
0.0~420.0
0.0~840.0
0~1680
Restrictions: Alarm response is returned for normal SET commands in the following conditions
・While operating as a parallel operation slave unit
・
Sequence operation in progress
<Ex.>
ZX-S-400LN(Idependent Operation)
CURR 40
CURR?
40.00
Summary of Contents for ZX-S-1600LAN
Page 1: ...Constant Voltage Constant Current DC Power Supply series Instruction Manual...
Page 13: ...About this Product 10 This is blank page...
Page 63: ...Useful Function 60 This is blank page...
Page 151: ...Controlling with External Analog Contact Signals 148 This is blank page...
Page 157: ...Special Loads 154 This is blank page...
Page 199: ...Specifications 196 This is blank page...
Page 200: ...197 External Diagrams ZX S 400LN 400LAN 4 M3...
Page 201: ...Appendix 198 ZX S 800LN 800LAN...
Page 202: ...Appendix 199 ZX S 1600LN 1600LAN...