Useful Function
------------------------------------------------------------------------------------
55
Sequential Operation will be started after pressing "OUTPUT" button.
"OUTPUT" lamp will be blinking once the sequential operation is started.
The sequential operation will be stopped, if the "OUTPUT"button is pressed
during the operation.
Please take note that the sequential operation is able to start or stop by
remote command or external contact.
Continue Mode Function
The sequential operation will be restarted from the latest status by setting "2" for the setting
item 100 even the output will be stopped during the sequential operation due to the error
and turning off of the ZX-S series.
(V)/(A)
(t)
tC
tC
tB1
tA
tA :Operating Time with Memory A
tB :Operating Time with Memory B
tB1:Operated time with Memory B
tB2:Remained operation time with
Memory B
tC :Operating Time for Memory C
tOff:Operating Time for OUTPUT OFF
Sequential Operation Start
tB2
OUTPUT STOP during
the opration Memory B
Sequential Operation Start
tB2
tB
tB
OUTPUT
PRESET
OVP
OCP
FUNC.
ALARM RESET
The "OUTPUT" lamp is blinking
during the sequential
operationsequence operation
Only the "OUTPUT" button, "DISPLAY" button,and "LOCK" button will
be enable during the sequential operation. Other buttons will be disable
during the operation.
NOTE
Summary of Contents for ZX-S-1600LAN
Page 1: ...Constant Voltage Constant Current DC Power Supply series Instruction Manual...
Page 13: ...About this Product 10 This is blank page...
Page 63: ...Useful Function 60 This is blank page...
Page 151: ...Controlling with External Analog Contact Signals 148 This is blank page...
Page 157: ...Special Loads 154 This is blank page...
Page 199: ...Specifications 196 This is blank page...
Page 200: ...197 External Diagrams ZX S 400LN 400LAN 4 M3...
Page 201: ...Appendix 198 ZX S 800LN 800LAN...
Page 202: ...Appendix 199 ZX S 1600LN 1600LAN...