Useful Function
------------------------------------------------------------------------------------
44
It is possible to continue to change other setting items without
pressing the “FUNC.” key. In this case, press the “FUNC.” key to
confirm settings once changes are complete.
When selecting Constant Voltage (CV) Priority,
Variable Slew Rate mode (Item 2 set to 2)
Set the Item Number to either 3 or 4
using the VOLTAGE dial.
Set Value 3=Rising Voltage Slew Rate
Set Value 4=Falling Voltage Slew Rate
Assign the set value using the CURRENT dial.
Range:0.1V/s~160.0V/s
When selecting Constant Current (CC) Priority,
Variable Slew Rate mode (Item 2 set to 3)
Set the Item Number to either 5 or 6
using the VOLTAGE dial.
Set Value 5=Rising Current Slew Rate
Set Value 6=Falling Current Slew Rate
Assign the set value using the CURRENT dial.
Range:
400LN/LAN : 0.01A/s ~ 80.00A/s
800LN/LAN : 0.1A/s ~ 160.0A/s
1600LN/LAN : 0.1A/s ~ 320.0A/s
If using with master slave parallel operation, see
caution on page 43.
Press the FUNC. key again to finish.
Confirms settings and returns the Number Display to
measurement display mode.
CC
CV
OUTPUT POWER (%)
STEP
CURRENT
STEP
VOLTAGE
PRESET FUNC. REMOTE LOCK
20
60
100 LMT
40
80
CC
CV
OUTPUT POWER (%)
STEP
CURRENT
STEP
VOLTAGE
PRESET FUNC. REMOTE LOCK
20
60
100 LMT
40
80
CC
CV
OUTPUT POWER (%)
STEP
CURRENT
STEP
VOLTAGE
PRESET FUNC. REMOTE LOCK
20
60
100 LMT
40
80
CC
CV
OUTPUT POWER (%)
STEP
CURRENT
STEP
VOLTAGE
PRESET FUNC. REMOTE LOCK
20
60
100 LMT
40
80
MEMO
OUTPUT
PRESET
OVP
OCP
FUNC.
ALARM RESET
Set to 5 or 6
Set to 3 or 4
Summary of Contents for ZX-S-1600LAN
Page 1: ...Constant Voltage Constant Current DC Power Supply series Instruction Manual...
Page 13: ...About this Product 10 This is blank page...
Page 63: ...Useful Function 60 This is blank page...
Page 151: ...Controlling with External Analog Contact Signals 148 This is blank page...
Page 157: ...Special Loads 154 This is blank page...
Page 199: ...Specifications 196 This is blank page...
Page 200: ...197 External Diagrams ZX S 400LN 400LAN 4 M3...
Page 201: ...Appendix 198 ZX S 800LN 800LAN...
Page 202: ...Appendix 199 ZX S 1600LN 1600LAN...