![TAKASAGO HX-S-G2 Series Instruction Manual Download Page 93](http://html1.mh-extra.com/html/takasago/hx-s-g2-series/hx-s-g2-series_instruction-manual_3330327093.webp)
Using via Digital Data Communication
93
[SOURce]:CURRent:SLEW:RISing
: Sets the CC Slew Rate Rising
Function:
Sets the CC slew rate for rising.
Same as FUNCTION Settings Item 4
Format:
[SOURce]:CURRent:SLEW:RISing <NRf>
Type:
SET command, QUERY command
Parameters:
Range varies depending on the total output capacity of the parallel connection.
Response:
Same as parameters
Model(Type)
Total Output
Capacity
Output Current Ranges (A/S)
30V Output Type
60V Output Type
500V Output
Type
1000V Output
Type
6kW
0.0 to 400.0
0.0 to 200.0
0.01 to 24.00
0.060 to 6.600
12kW
0.0 to 800.0
0.0 to 400.0
0.01 to 48.00
0.12 to 13.20
18kW
0 to 1200
0.0 to 600.0
0.01 to 72.00
0.18 to 19.80
24kW
0 to 1600
0.0 to 800.0
0.01 to 96.00
0.24 to 26.40
30kW
0 to 2000
0 to 1000
0.1 to 120.0
0.30 to 33.00
36kW
0 to 2400
0 to 1200
0.1 to 144.0
0.36 to 39.60
42kW
0 to 2800
0 to 1400
0.1 to 168.0
0.42 to 46.20
48kW
0 to 3200
0 to 1600
0.1 to 192.0
0.48 to 52.80
54kW
0 to 3600
0 to 1800
0.1 to 216.0
0.54 to 59.40
60kW
0 to 4000
0 to 2000
0.1 to 240.0
0.60 to 66.00
66kW
0 to 4400
0 to 2200
0.1 to 264.0
0.66 to 72.60
72kW
0 to 4800
0 to 2400
0.1 to 288.0
0.72 to 79.20
78kW
0 to 5200
0 to 2600
0.1 to 312.0
0.78 to 85.80
84kW
0 to 5600
0 to 2800
0.1 to 336.0
0.84 to 92.40
90kW
0 to 6000
0 to 3000
0.1 to 360.0
0.90 to 99.00
96kW
0 to 6400
0 to 3200
0.1 to 384.0
1.0 to 105.6
102kW
0 to 6800
0 to 3400
0.1 to 408.0
1.0 to 112.2
108kW
0 to 7200
0 to 3600
0.1 to 432.0
1.1 to 118.8
114kW
0 to 7600
0 to 3800
0.1 to 456.0
1.1 to 125.4
120kW
0 to 8000
0 to 4000
0.1 to 480.0
1.2 to 132.0
Restrictions:
Alarm response is returned for normal SET commands in the following conditions
·
Cases other than full-featured type "model name with F"
·
While operating as a series operation slave unit
·
While operating as a parallel operation slave unit
<Ex.>
CURR:SLEW:RIS 400.0
CURR:SLEW:RIS?
400.0
Summary of Contents for HX-S-G2 Series
Page 165: ...Special Loads 165 This page is blank...
Page 169: ...Maintenance 169 This page is blank...
Page 211: ...Specifications 211 External Diagrams 1 HX S 030 200G2 F I...
Page 212: ...Specifications 212 2 HX S 030 400G2 F I...
Page 213: ...Specifications 213 3 HX S 060 100G2 F I...
Page 214: ...Specifications 214 4 HX S 060 200G2 F I...
Page 215: ...Specifications 215 5 HX S 0120 50G2 F I...
Page 216: ...Specifications 216 6 HX S 0120 100G2 F I...
Page 217: ...Specifications 217 7 HX S 0400 15G2 F I...
Page 218: ...Specifications 218 8 HX S 0400 30G2 F I...
Page 219: ...Specifications 219 9 HX S 0500 12G2 F I...
Page 220: ...Specifications 220 10 HX S 0500 24G2 F I...
Page 221: ...Specifications 221 11 HX S 01000 6G2 F I...
Page 222: ...Specifications 222 12 HX S 01000 12G2 F I...
Page 223: ...Specifications 223...
Page 239: ......