Controlling with External Analog & Contact Signals
135
Controlling with External Analog & Contact Signals
Using External Control Terminals
This section covers proper methods when operating the HX-S-G2 Series Power Supply externally.
On the rear panel of this power supply, there are the connector for external control and the connector for isolation control,
which can be applied and used for various purposes combined with the FUNCTION items.
A specialized connecting connector is attached to the external control connector.
(Attached to the power supply)
Insulation Control
Connector
Seriese Control Connector
External Control Connector
1
16
1
13
14
26
Lock Lever
Maker : Phaenix Contact
Type : DFMC1,5/13ST3,5LR
Cat.No.: 1790593
Maker : Phoenix Contact
Type : MC1.5/16-STF-3.81
Cat.No.: 1827842
MEMO
MEMO
How to insert wire into external control connector
① Push in a flat-head screwdriver to the lever of the hole upper part of a c
connector.
② Keeing pushing the flat head scredriver, insert a cable(wire)
②
to the round hole.
② ※※
Spring Connection
② ※※
No pin is rewuired for connecting
Wire
③ Extract Screwdriver
・Wire Size:24-16AWG(UL)
・Stripped Length:10.0mm
10.0mm
2.5mm
0.4mm
How to insert wire into insulation control connector
① Turn the screw at the upper part of the connector counterclockwise
①
using a flat head screwdriver to widen the connection insertion part.
Flat-Head Screwdriver
①
Wire Specifications
・Wire Size:28-16AWG(UL)
・Stripped Length:7.0mm
7.0mm
Flat-Head Screwdriver
Dimensions
2.0mm
0.4mm
Flat-Head
Screwdriver
② Insert a cable(wire) into the connection insertion part and turn the
screw at the upper part of the connector clickwise using a flat head
screwdriver to connect the cable.
Flat-Head Screwdriver
Flat-Head
Screwdriver
Flat-Head Screwdriver
Flat-Head Screwdriver
Flat-Head Screwdriver
Wire
Wire Specifications
Flat-Head Screwdriver
Dimensions
●
Isolation for the wire connecting to the external control should be more than the relative ground voltage of this
product.
Otherwise, the user may receive electric shock.
●
There is no connector for external control for 1000V type model.
Please mount the isolated control connector when the external control is required.
●
Please do not touch the external control connector terminal and isolated control connector terminal
after turning on the "Power SW".
!
CAUTION
Summary of Contents for HX-S-G2 Series
Page 165: ...Special Loads 165 This page is blank...
Page 169: ...Maintenance 169 This page is blank...
Page 211: ...Specifications 211 External Diagrams 1 HX S 030 200G2 F I...
Page 212: ...Specifications 212 2 HX S 030 400G2 F I...
Page 213: ...Specifications 213 3 HX S 060 100G2 F I...
Page 214: ...Specifications 214 4 HX S 060 200G2 F I...
Page 215: ...Specifications 215 5 HX S 0120 50G2 F I...
Page 216: ...Specifications 216 6 HX S 0120 100G2 F I...
Page 217: ...Specifications 217 7 HX S 0400 15G2 F I...
Page 218: ...Specifications 218 8 HX S 0400 30G2 F I...
Page 219: ...Specifications 219 9 HX S 0500 12G2 F I...
Page 220: ...Specifications 220 10 HX S 0500 24G2 F I...
Page 221: ...Specifications 221 11 HX S 01000 6G2 F I...
Page 222: ...Specifications 222 12 HX S 01000 12G2 F I...
Page 223: ...Specifications 223...
Page 239: ......