Basic Usage
42
Canceling Over Voltage Protection Operation
When Over Voltage Protection Circuit (OVP) is triggered, the
OUTPUT is set to OFF and an error code and the alarm message
will be displayed in the Number Display (voltage) and the Number
Display (current).
The error code "E004" is displayed in the Number Display
(voltage) and "OUP" blinks in the Number Display (current).
Hold down the ALARM RESET key for more than 1 second to
erase the displayed error code and OUP.
Remove cause which triggered the OVP
(Change CV set values, OVP set values, load status)
Press the OUTPUT key to start output.
When the OVP is triggered, the Falling slew rate setting by the
slew rate function becomes invalid and the voltage is decreased
most rapidly under the condition of that time point.
MEMO
● During serial data communication, recovery from alarm status
is possible using commands.
● During parallel operation where the Master unit is the
operating normal, if any Slave unit triggers an alarm, the error
code “E006” will be displayed in the Master and functioning
Slave units.
(Information concerning the alarm will be displayed on the Slave
unit that triggered the alarm)
MEMO
If the error code and OVP are not erased after holding down the
ALARM RESET key, the power supply may be damaged. Turn
power off immediately and please contact Takasago or your
retail store.
Caution
Summary of Contents for HX-S-G2 Series
Page 165: ...Special Loads 165 This page is blank...
Page 169: ...Maintenance 169 This page is blank...
Page 211: ...Specifications 211 External Diagrams 1 HX S 030 200G2 F I...
Page 212: ...Specifications 212 2 HX S 030 400G2 F I...
Page 213: ...Specifications 213 3 HX S 060 100G2 F I...
Page 214: ...Specifications 214 4 HX S 060 200G2 F I...
Page 215: ...Specifications 215 5 HX S 0120 50G2 F I...
Page 216: ...Specifications 216 6 HX S 0120 100G2 F I...
Page 217: ...Specifications 217 7 HX S 0400 15G2 F I...
Page 218: ...Specifications 218 8 HX S 0400 30G2 F I...
Page 219: ...Specifications 219 9 HX S 0500 12G2 F I...
Page 220: ...Specifications 220 10 HX S 0500 24G2 F I...
Page 221: ...Specifications 221 11 HX S 01000 6G2 F I...
Page 222: ...Specifications 222 12 HX S 01000 12G2 F I...
Page 223: ...Specifications 223...
Page 239: ......