4.4.3 Other configuration
4.4.3.1 Output channel configuration
To distribute the interpretation languages separately,
A/B/C channels are provided in the interpreter unit.
When the interpreter unit menu configuration is finished,
the output channel of every interpreter unit must be
setup before the meeting and according to the actual
requirements.
a. Output channel A is setup at the CMU, and its output
language is a fixed language as the output of the
booth;
b.
Output channel C is used to output a
non-conventional language. Output channel C can
be setup as “None” or “All” from the CMU menu
configuration (refer to section 2.4.2).
If output channel C is set as “All”, when the output
channel C switch was pressed, push the primary
knob to go to channel 1, turn the primary knob to
select the output language. If the output channel C is
activated, the output of this interpreter unit will be
distributed to all booths which set this booth as their
auto relay booth, and other interpreters can do relay
interpretation. Now, the output language of the
output channel B is a fixed language as the output of
the booth at the CMU menu configuration (refer to
section 2.4.2);
If the output channel C is set as “None”, the output
channel B is used to output a non-conventional
language. Output channel B can be setup as “None”
or “All” from the CMU menu configuration. If the
output channel B is set as “All”, when the output
channel B switch was pressed, push the primary
knob to go to channel 1, turn the primary knob to
select the output language. If the output channel B is
activated, the output of this interpreter unit will be
distributed to all booths which set this booth as their
auto relay booth, and other interpreters can do relay
interpretation.
4.4.3.2 Interlock mode
Interpretation mode can be setup by menu operation
on the main unit (refer to section 2.4.2):
Interlock mode between booths
:
OVERRIDE
: allows an interpreter to override
another interpreter in another interpreter booth
supplying the same interpretation channel;
BC-OVERRIDE
: enables B/C channel of an
interpreter in another booth to override an occupied
A channel in another booth, but supplying the same
channel; when an interpreter in another booth to
override an occupied B/C channel in another booth,
the “Microphone ON” indicators the occupied B/C
channel will flash on the control panel for about 5
seconds;
INTERLOCK
: blocks another interpreter from using
the same channel in another interpreter booth. As a
warning that another microphone is active on a
given channel, when a second one is activated on
the same channel, the “Microphone ON” indicators
will flash on the control panel for about 5 seconds.
Interlock mode in a booth:
OVERRIDE:
enables an interpreter in a booth to
override an occupied channel in the same booth,
but supplying the same channel;
INTERLOCK:
prevents that two interpreters
engage the same channel in the same booth.
4.4.3.3 Playback time configuration
In standby interface, press and hold the “Mute” key and
rotate the primary knob
⑥
clockwise to go to the
playback time configuration. Rotate the primary knob
⑥
to set the playback time within a range between 2 s -
6 s.
Summary of Contents for HCS-4100/50 Series
Page 46: ...33 Figure 2 10 Floor mode setting Normal Mode Figure 2 11 Floor mode setting Insert Mode...
Page 47: ...34 Figure 2 12 Floor mode setting Sync Line Out1 Mixer...
Page 59: ...46 Figure 3 4 Cutout of HCS 48U8 series flush mounted congress unit unit mm...
Page 61: ...48 Figure 3 6 Cutout of HCS 48U9DFFF flush mounted congress unit unit mm...
Page 62: ...49 3 2 2 2 Installation Figure 3 7 Installation of HCS 48U7 series flush mounted congress unit...
Page 63: ...50 Figure 3 8 Installation of HCS 48U8 series and HCS 48U9 series flush mounted congress unit...
Page 65: ...52 Figure 3 11 Disassembly caution of HCS 48U8 and HCS 48U9 series flush mounted congress unit...
Page 130: ...117 Figure 3 43 Installation of HCS 4325U 50 congress unit unit mm...
Page 143: ...130 Figure 3 57 Multi function connector connected to the HCS 4341 50 series congress unit...
Page 155: ...141 Figure 3 72 Multi function connector connected to HCS 4841 42 43 series congress units...
Page 170: ...156 4 1 Functions and indications Front Side Bottom Figure 4 1 HCS 4385U 50 Interpreter unit...
Page 223: ...www taiden com TAIDEN INDUSTRIAL CO LTD Copyright by TAIDEN Last Revision 06 2013...