3.9 HCS-4341/50 series congress unit
3.9.1 Functions and indications
3.9.1.1 HCS-4341/50 series congress unit
Front of HCS-4341CB/50
boundary chairman unit
Front of HCS-4341DB/50
boundary delegate unit
Bottom of HCS-4341B/50
HCS-4341HD/50 flush-mounted
delegate unit
Figure 3.51 HCS-4341/50 series congress units
Figure 3.51:
1. Priority key with indicating light (for the
chairman unit only):
According to the priority mode configuration on the
main unit:
◊
If configured as “All mute”, all active delegate
and VIP microphones will be muted temporarily
when this key is pressed and they will resume
when the key is released;
◊
If configured as “All off”, all active delegate
microphones will be switched off when this key is
pressed. All active VIP microphones will be
muted temporarily and will resume when the key
is released; under “Open” and “Apply” mode,
pressing this key will clear the request list (deny
all delegates’ requests to speak);
If the chairman microphone is not active, pressing
this key will activate it.
2. Microphone On/Off key with indicating light (for
the chairman unit)
Microphone/request key with indicating light (for
the delegate unit):
Chairman unit: press this key to activate the
microphone;
Delegate unit: press this key to activate/deactivate
the microphone or request/cancel
request to speak.
(Refer to section 3.9.4 for details)
Work state
Indicating light
Microphone On
Red (on)
Speaking time limit
Red (flash)
3. Cat.5 cable with standard RJ45 plug, connecting
to “Mic.” socket of multi-function connector
4. Bass cut switch (switch down is on)
200 Hz, -3 dB
5. Treble cut switch (switch down is on)
8 kHz, -3 dB
6. Cable with a 6P mini DIN plug to connect to
“Handheld Mic.” socket of multi-function
connector
Summary of Contents for HCS-4100/50 Series
Page 46: ...33 Figure 2 10 Floor mode setting Normal Mode Figure 2 11 Floor mode setting Insert Mode...
Page 47: ...34 Figure 2 12 Floor mode setting Sync Line Out1 Mixer...
Page 59: ...46 Figure 3 4 Cutout of HCS 48U8 series flush mounted congress unit unit mm...
Page 61: ...48 Figure 3 6 Cutout of HCS 48U9DFFF flush mounted congress unit unit mm...
Page 62: ...49 3 2 2 2 Installation Figure 3 7 Installation of HCS 48U7 series flush mounted congress unit...
Page 63: ...50 Figure 3 8 Installation of HCS 48U8 series and HCS 48U9 series flush mounted congress unit...
Page 65: ...52 Figure 3 11 Disassembly caution of HCS 48U8 and HCS 48U9 series flush mounted congress unit...
Page 130: ...117 Figure 3 43 Installation of HCS 4325U 50 congress unit unit mm...
Page 143: ...130 Figure 3 57 Multi function connector connected to the HCS 4341 50 series congress unit...
Page 155: ...141 Figure 3 72 Multi function connector connected to HCS 4841 42 43 series congress units...
Page 170: ...156 4 1 Functions and indications Front Side Bottom Figure 4 1 HCS 4385U 50 Interpreter unit...
Page 223: ...www taiden com TAIDEN INDUSTRIAL CO LTD Copyright by TAIDEN Last Revision 06 2013...