Coral FlexiCom 6000 Installation Manual
Hardware Installation Procedure
2-21
Eq
uipment Insta
llation
2
connector firmly into the Coral I/O connector. Carefully pull the
hook-and-loop fastener strap tight and press the strap back onto itself, securing
the cable connector into the Coral I/O connector. Route the other end of the
cable to the appropriate cable punch block on the MDF. Repeat this procedure
for each I/O cable, moving from right to left across the lower I/O connectors,
and then from right to left across the upper I/O connectors. When all sixteen
I/O cables are installed on the lower peripheral shelf, move up to the
peripheral shelf above, until all the required I/O cables are in place.
Table 2-4
I/O Champ
Connector to Card Slot
Relationships
Coral I/O Champ
Connectors
Associated Card Slots
J37, J38
3, 4
J39, J40
5, 6
J41, J42
7, 8
J43, J44
9, 10
J45, J46
11, 12
J47, J48
13, 14
J49, J50
15, 16
J51, J52
17, 18
Never route RJ-45 cables through the bottom, as this may cause RFI
disturbances within the system. For further information, see