technical reference
3
31
Synrad
Firestar i401
operator’s manual
Firestar i401 general specifications
Parameter
Firestar
i401
Cooling Specifications
Maximum Heat Load ....................................6000 Watts (20.5 kBtu/hr)
Flow Rate (minimum) ..................................4 GPM at < 60 PSI (15 lpm at < 4.1 bar)
Pressure Drop .................................................10 PSI at 4 GPM (0.6 bar at 15 lpm)
Coolant Temperature
10
.................................18 °C to 22 °C
Environmental Specifications
Operating Temperature
11
..............................15 °C – 40 °C
Humidity .......................................................0–95%, non-condensing
Physical Specifications
Length ...........................................................48.3 in (122.7 cm)
Width ............................................................ 8.2 in (20.8 cm)
Height ...........................................................11.8 in (30.0 cm)
Weight ...........................................................130 lbs (59.0 kg)
* Specifications subject to change without notice.
10 Firestar i401 lasers can be operated at coolant temperatures up to 28 °C (82 °F) in order to reduce problems associated with
condensation; however, this may result in decreased laser performance and/or reduced laser lifetime.
11 Published specifications guaranteed at a cooling temperature of 20 °C.